![Welbilt C4 EB 12.20 Installation Manual Download Page 95](http://html.mh-extra.com/html/welbilt/c4-eb-12-20/c4-eb-12-20_installation-manual_953843095.webp)
9.21 Dissipated heat
C4 EB/ES
10.10
20.10
20.20
With appliance door closed
Latent heat
[kJ/h]
[kW]
6900
1.92
6900
1.92
11000
3.06
Sensible heat
[kJ/h]
[kW]
7800
2.17
8900
2.47
14100
3.92
C4 GB/GS
12.20
20.10
20.20
With appliance door closed
Latent heat
[kJ/h]
[kW]
8200
2.28
7100
1.97
12200
3.39
Sensible heat
[kJ/h]
[kW]
11000
3.06
11000
3.06
15400
4.28
9.22 Water connection
C4 EB/ES/GB/GS
Water supply (cold only)
Shut-off device
With EA (verifiable) check valve and dirt filter
Water supply
2 x G 3/4'' fixed connection, optionally including
connecting pipe (min. DN13 / 1/2'')
Flow pressure
[kPa]
150 - 600 (1.5 - 6 bar)
Pressure gauge in the water supply
[kPa]
150 (1.5 bar)
Water drain
Model
Fixed connection (recommended) or open tank
or channel/gully
Type
DN
50
Waste water temperature
[°C]
max. 80
Slope for drain pipe
min. 3.5% (2°)
Safety overflow
[mm]
80 x 25 mm
C4 EB/ES/GB/GS (for United Kingdom)
Water supply (cold only)
Shut-off device
With double check valve (type BA or CA) and
dirt filter
Water supply
2 x G 3/4'' fixed connection, optionally including
connecting pipe (min. DN13 / 1/2'')
Flow pressure
[kPa]
150 - 600 (1.5 - 6 bar)
Pressure gauge in the water supply
[kPa]
150 (1.5 bar)
Water drain
Model
Fixed connection (recommended) or open tank
or channel/gully
Type
DN
50
9 Technical data
Installation manual
95