6.6.2 Connecting the fully automatic oven cleaning system
Connecting the fully automatic oven cleaning system to canisters
1.
Mix the supplied ConvoCare Kconcentrate with soft water in the empty
ConvoCare rinse aid canister.
Follow the instructions in the user manual on mixing the ConvoCare
rinse aid in the canister.
2.
Plug the green extractor tube (2) for the ConvoCare rinse aid onto the
connector nipple of the rear tube fitting (F) and secure the tube in
place with the wire clip (3) (see label for rinse-aid connection on the
left-hand side of the appliance).
3.
Insert the suction nozzle on the green extractor tube (2) into the rinse
aid canister (1). There must be no kinks in the tube and the vent hole
in the canister must be open and unblocked.