background image

 
 

FROSTWATCH 

 

Temperature 

Monitor unit                              

v3.20

                  

 
 

 

 
 
 
 
 
 
 
 
 
 
USER MANUAL    (All Models)                        

 

 

 

 

Summary of Contents for FROSTWATCH

Page 1: ...FROSTWATCH Temperature Monitor unit v3 20 USER MANUAL All Models...

Page 2: ...5 7 3 View I O status 14 5 7 4 Set fault output 14 5 8 Phone alarm 15 5 8 1 Setup contacts 15 5 8 2 Ph call attempts 16 5 8 3 Repeat TXT messages 16 5 8 4 Signal strength 17 5 8 5 System ph number 17...

Page 3: ...ostWatch has built in It is possible to upgrade your FrostWatch to a higher featured version by returning it to the manufacturer Please contact the manufacturer for details of this upgrade service Pow...

Page 4: ...ally to minimise inadvertent adjustment of settings Info Key to allow settings and logged values to be displayed without opening the case Backlit Liquid Crystal Display allows viewing in the dark Reco...

Page 5: ...acid battery mounting bracket to suit 10WSOL solar panel and waterproof enclosure to fit battery and any 12VDC model of FrostWatch TSENSE Additional Temperature Probe Please Specify Length TCABLE Cus...

Page 6: ...A2 and GND 6 Connect the input power leads battery or plug pack provided to the Power In terminals Note that both AC and DC supplies can be connected either way around All Models 7 Ensure wiring is c...

Page 7: ...control mode the alarm will operate when the temperature has been equal to or below the alarm on point for the required on delay time The alarm will reset when the temperature rises above the alarm of...

Page 8: ...ie No power is being supplied to the FrostWatch Unit Phone Signal Good Symbol To Check Signal strength with greater resolution see section 5 8 4 under device settings System Messages Messages here inf...

Page 9: ...rk Screens 2 5 Shows the Highest and Lowest recorded temperatures today and since the last time the log was cleared Screens 15 16 Shows the Frost Alarm and Sunburn Alarm on point temperatures and whic...

Page 10: ...nter the main menu Using the DOWN or UP key rotate through the main menu until the desired option is displayed on line 2 then press the ENTER key MAIN MENU Frost alarm Line 1 Line 2 MENU LISTING 1 Fro...

Page 11: ...Using the DOWN or UP key increase or decrease the on delay time This is the amount of time in minutes the temperature must be continuously at or below the alarm on point before the alarm will operate...

Page 12: ...e DOWN or UP key increase or decrease the on delay time This is the amount of time in minutes the temperature must be continuously at or above the alarm on point before the alarm will operate Press th...

Page 13: ...nu to set the system time and date this needs to be set to allow accurate time and date stamping for all logged events Step 1 Using the DOWN or UP key modify the value pointed to by the flashing curso...

Page 14: ...cter slot pointed to by the flashing cursor ENTER will move the cursor to the next character slot To exit this menu press ENTER through each of the character slots 5 6 3 Setup backlight Using the DOWN...

Page 15: ...cations e g TXT Step 1 Using the DOWN or UP key select the desired input output to setup Press the ENTER key to proceed Step 2 Using the DOWN or UP key enable or disable the input output Press the ENT...

Page 16: ...from when the pump mode relay O1 is activated Press the ENTER key to proceed Step 3 if input D1 is enabled Using the DOWN or UP key select either enable or disable If Low Pressure Cutout is enabled t...

Page 17: ...f the character slots Step 3 Using the DOWN or UP key select the required contact mode disable Phone TXT Ph TXT for the selected contact during Frost Alarm events Press the ENTER key to store the sett...

Page 18: ...ated Network TXTs 5 8 2 Ph call attempts With the ph call attempts menu option chosen from the phone alarm menu the screen will now display the message below Using the DOWN or UP key adjust the amount...

Page 19: ...or better 5 8 5 System ph number Selecting the system ph number menu option displays the units phone number Press any key to return to the phone alarm menu 5 8 6 TXT command password This allows passw...

Page 20: ...displayed Using the DOWN or UP key rotate through the menu until the desired option is displayed on line 2 then press the ENTER key 6 2 Calibrate low point Done where the temperature is below 5 0 c S...

Page 21: ...he ENTER key to proceed 6 4 Restore defaults In the event that calibration of the unit is not performed correctly and you have no means of getting the unit to a known accurate temperature FrostWatch h...

Page 22: ...nds confirmation TXT 4digit password STOP Stops dialling the contact list during alarm events Sends confirmation TXT 4digit password TXT Stops further Repeat TXT messages during alarm events Sends con...

Page 23: ...ived from the sensor is either excessively low or high This can be caused by reversed sensor wires liquid within the sensor or cable or cable damage signal Internal phone has no reception Check that t...

Page 24: ...nd line phone and follow the instructions 9 1 2 Over the internet www vodafone co nz You can top up using your credit card on the Vodafone website 9 1 3 Other ways Over the phone with your credit card...

Page 25: ...Explanation of calculations used 10 3 Temperature rate of change The Temperature rate of change in degrees per hour is calculated from the primary temperature sensor input A1 This updates every minut...

Page 26: ...optional output Digital Input 1 D1 On Off inputs e g pressure switch Digital Input 2 D2 On Off inputs e g pressure switch Digital Input 3 D3 On Off inputs Digital Input 4 D4 On Off inputs Analogue In...

Page 27: ...d Blue Connect the Brown wire to input A1 or A2 if using this input Connect the Blue wire to the GND terminal of the same connector Red and Black Connect the Red wire to input A1 or A2 if using this i...

Page 28: ...of water or due to chemical contamination of ANY form Willowbank Electronics Ltd reserves the right to repair or replace any unit returned under warranty at its discretion All warrantees are offered...

Page 29: ...ght disabled timed enabled Buzzer disabled timed enabled Hardware Setup A1 disabled enabled Name __ __ __ __ __ __ __ __ __ __ A2 disabled enabled Name __ __ __ __ __ __ __ __ __ __ D1 disabled enable...

Page 30: ...able TXT Prewarn Disable TXT Sunburn Alarm Disable Phone TXT Ph TXT Repeat Disable TXT Prewarn Disable TXT System TXT Disable TXT Contact 3 Phone Number __ __ __ __ __ __ __ __ __ __ __ __ __ __ Frost...

Page 31: ...rial No _______________ Date of purchase ______ ______ ___________ Purchased from _____________________________________________________ Name __________________________________________________________...