Commissioning
The signal must be available with a rising edge of the start signal; it determines the direction of rotation
(outputs
C
and
E
).
8.2.2 Terminal 2
Enable (RESET/STOP)
This input must be wired.
LOW
-Disable (motor STOP)
-Reset Alarm
HIGH
-Enable
If the level is LOW, all movements are locked, including manual mode. The outputs
C
and
E
(motor
contactor) as well as the output
D
(holding brake) are immediately switched off.
8.2.3 Terminal 3
Start (edge-triggered)
A LOW/HIGH edge starts a complete cycle. The
start pulse must have a pulse width of at least
20 msec.
If the level remains HIGH, this does not trigger a
new start.
The jumper
N-2H
must be at the left position. The
terminal
H
has no effect.
8.2.4 Terminal 5
Stop
If the level is HIGH, start signals are ignored and movements are stopped.
8.2.5 Terminal F
Sensor
The sensor at the rotary indexing table/rotary indexing ring is connected to this terminal. It provides the
signal that the position cam has been reached and triggers a stop of the motor.
8.2.6 Terminal G
Manual mode holding brake
A HIGH signal release the holding brake. A start of the rotary indexing table/rotary indexing ring is not
possible.