![WEISS 3RT2017-1BB42 Manual Download Page 126](http://html.mh-extra.com/html/weiss/3rt2017-1bb42/3rt2017-1bb42_manual_953402126.webp)
Manual R06-2016
126 / 172
ROTARY INDEXING TABLE CONTROLLER EF2...B
OPERATION / DESCRIPTION OF WEISS SOFTWARE |
8.5 Operation and Monitoring
8.5.4 Statistical data
Fig. 76: Statistical data
The "Statistical data" section shows statistical data that was recorded during operation.
In this section, a number of cycles (1) for the rotary indexing table can be set as a service interval.
The rotary indexing table cycles are counted and the counter value is displayed in the "Current counter service inter-
val" (2).
The current counter value Service interval can be reset by the operator - e.g. after performing service (3).
When the number of cycles for the service interval has been reached, a message is issued. The message is deacti-
vated by an input value of 0.
When using applications up to SIL2, the following statistical data can be reset individually by an operator - e.g. after
performing service (4).
Cycle counter (counter of user)
Counter of incorrect power supply switches (counter of user)
Counter switching cycles motor holding brake
Rotary indexing table operating hours
Motor operating hours
When using applications after SIL3, the counter for motor contactor switching cycles can be reset additionally.
As an alternative, all statistical data mentioned above can be reset together (5).
All other data is informative for the operator and can only be reset by the service personnel from
WEISS GmbH.
1
2
3
4
5
SIL3