Installation and operating instruction
Hydraulic unit WWP LS 8 ... 16-B
6 Operation
83306902 2/2017-05 La
36-88
6.4.2 Set DHW setpoint temperature
Select temperature level using the dial knob and confirm.
The display changes to the setting mode.
Press the dial knob and set the desired temperature.
Press dial knob and confirm entry.
User
50.0°C
Normal
40.0°C
Setback
User
Normal
50.0°C
Factory setting 50.0°C
Press ESC > 3 sec
User
Normal
55.0°C
Factory setting 50.0°C
Press ESC > 3 sec
The DHW setpoint temperature should now be set as required.
The electric heating is switched on in addition for DHW setpoint temperatures with
a flow setpoint above 55 °C. The flow setpoint results from the DHW setpoint tem-
perature and the flow super-elevation [ch. 6.7.4.5].