9.4 Replacing electrodes
Observe notes on servicing (see Ch. 9).
Ignition electrode
▶
Remove the ignition plug
5
and the earth wire
3
.
▶
Remove bolts
4
.
▶
Replace ignition electrode
2
and gasket
1
, whilst observing the ignition electrode
distance of 4.0 mm.
Ionisation electrode
▶
remove plug (X14)
4
and earth wire
5
from boiler electronics.
▶
Remove bolts
2
.
▶
Replace ionisation electrode
3
and gasket
1
.