3 Product description
83309302 1/2018-05 La
24-196
3.5.6 Rating
Condensing boiler
WTC 15
WTC 25
Combustion heat rating Q
C
2.0 … 14.0 kW
3.0 … 24.0 kW
Boiler capacity at 80/60 °C
1.9 … 13.7 kW
2.9 … 23.6 kW
Boiler capacity at 50/30 °C
2.1 … 15.1 kW
3.3 … 26.0 kW
Fan speed Natural Gas
940 … 5200 1/min
(rpm)
980 … 6185 1/min
(rpm)
Fan speed Liquid Petroleum Gas
890 … 4850 1/min
(rpm)
900 … 5680 1/min
(rpm)
Condensate quantity at 50/30 °C
0.27 … 1.27 l/h
0.38 … 2.17 l/h
Fresh water storage
WAS 100
WAS 80 Power
WAS 115 Power
WTC 15
WTC 25
WTC 15
WTC 25
WTC 15
WTC 25
Continuous output
(60/10/45 °C)
14.1 kW
20.4 kW
14.5 kW
28.0 kW
14.5 kW
29.1 kW
Tapping volume
(60/10/45 °C)
344 l/h
507 l/h
351 l/h
671 l/h
351 l/h
713 l/h
Coefficient of performance
(1
(60/10/45 °C)
1.0
(1
1.2
(1
1.1
(1
1.8
(1
1.8
(1
2.7
(1
Short-term output
(1
(60/10/45 °C)
143 l/10 min 155 l/10 min 147 l/10 min 186 l/10 min 186 l/10 min 223 l/10 min
(1
If the storage temperature is low, the coefficient of performance is reduced.
WTC 25 with WAS ... Power
Combustion heat rating Q
C
at booster operation
28.0 kW
Fan speed Natural Gas at booster operating
7200 1/min (rpm)
Fan speed LPG at booster operation
6855 1/min (rpm)