Installation and operating instruction
Oil burner WM-L20/2-A R (W-FM100/200)
9 Servicing
83252902 1/2019-09 La
51-84
9.6 Removing and refitting air damper actuator
Observe notes on servicing [ch. 9.1].
Removing
Remove actuator cover.
Unplug plug and remove cable entry gland
1
.
Undo locknut
2
on the coupling.
Remove screws
3
.
Remove actuator from the coupling.
1
2
3
Refitting
Refit actuator in reverse order, ensuring correct alignment of shaft key.
Check address and Bus termination, see installation and operating manual Com-