Installation and operating instruction
Oil burner WM-L20/2-A R (W-FM100/200)
4 Installation
83252902 1/2019-09 La
26-84
4.4 Burner installation
Fit flange gasket
3
and hinged flange
2
to the boiler plate using screws
1
.
The aperture between combustion head and refractory should be filled with
flame-proof, resilient insulating material. Do not make solid.
2
3
1
Using suitable lifting equipment lift burner and, using hinge pins
1
fit into hinged
flange, observe pivoting direction.
Without combustion head extension
Close burner and secure with dome nut
2
.
1
2