Installation and operating instruction
Gas burner WG40…/1-A ZM-LN
9 Servicing
83300002 1/2019-02 La
82-128
9.12 Replacing double gas valve coil
Observe notes on servicing [ch. 9.1].
Ensure correct voltage and solenoid number when replacing the solenoid coil.
Undo screw(s)
1
.
Remove cap
2
.
With DMV also remove metal plate
4
.
Replace solenoid coil
3
.
DMV 5065 / DMV 5080
DMV 525
W-MF 5xx
3
3
3
4
4
2
2
2
1
1
1
1
1