© 2022 WEINZIERL ENGINEERING GmbH
Seite 5/36
3 Reset to factory default settings
It is possible to reset the device to its factory default settings.
The battery voltage has to be more than 2.6 V.
▪
Remove the battery from the device.
▪
Press the KNX programming button
❷
to discharge all capacitors.
▪
Press the KNX programming button
❷
and keep it pressed down.
▪
Insert the battery into the device.
▪
Keep the KNX programming button
❷
pressed for at least another 6 seconds.
▪
A short flashing of all LEDs (
❷❼❽
) visualizes the successful reset of the device to
factory default settings.
In the factory default settings, the device has the physical address 15.15.255 and no group
addresses are connected. Also, KNX Data Security is disabled and the initial key (FDSK) must be
used for secure commissioning.
The device can be used as an EnOcean rocker.
4 Operation as EnOcean device
In the factory default settings, the device can be operated as an EnOcean rocker (EEP F6-02-03,
compatible with F6-02-01), in this case the device operates unencrypted.
EnOcean encryption can be activated by simultaneously pressing the buttons A0
❸
and A1
❹
, or
B0
❺
and B1
❻
, for which purpose the rocker may have to be removed. By pressing all 4 buttons
(A0, A1, B0, B1) simultaneously, the insert works again without encryption.
After configuration via ETS, the EnOcean protocol is deactivated. It can be reactivated by resetting
to factory default settings.