Installation and Startup Guide
This document covers the installation of
cMT3090
Series HMI, for the detailed specifications and operation,
please refer to Brochure and EasyBuilder Pro User Manual.
Install Environment:
NEMA Rating
cMT3090 Series HMI is NEMA 4 rated (Indoor Only).
Electrical
Environment
cMT3090 Series has been tested to conform to European CE requirements. This
means that the circuitry is designed to resist the effects of electrical noise. This
does not guarantee noise immunity in severe cases. Proper wire routing and
grounding will insure proper operation.
Environmental
Considerations
(1) Make sure that the displays are installed correctly and that the operating
limits are followed. Avoid installing units in environments where severe
mechanical vibration or shocks are present.
(2)
Do not operate the unit in areas subject to explosion hazards due to
flammable gases, vapors or dusts.
(3) Do not install the unit where acid gas, such as SO2 exists.
(4)
This device should be mounted in the vertical position and for use on the flat
surface enclosure.
(5)
Conform to UL508 (ISBN 0-7629-0404-6) machine safety for use in
Pollution Degree 2 Environment.
Unpacking the Unit
Unpack and check the delivery. If damage is found,
notify the supplier.
The packing box can be transformed into an HMI stand. Please follow the steps to make the stand.
1. Remove the center of the box cover along the perforated line.
2. Pull the two inner flaps.
3. Press down along the perforated line inside the box.
4. Complete the stand as shown.
Installation Instructions
Secure the operator panel in position, using all the fastening holes and the provided brackets
and screws. Screw Torque: 2.6 ~ 3.9 lbf.in. (For reaching waterproof effect and preventing the panel from
being deformed.)
Type
A(mm)
B(mm)
cMT3090
250
192
Power Connections
System Settings
When HMI is powered up and displays image, press
the round Start Button in the upper-left corner of the
screen to open the Setting dialog box. Tap the lock
icon
and log in. (Default System Password:
111111)
Go to the Network tab, and setup your network.
In Setting dialog box you can see device information,
configure general settings, set HMI Time/Date/Name,
and more.
cMT3090 series
Installation Instruction
NOTE:
Place the operator panel on a stable
surface during installation. Dropping it or
letting it fall may cause damage.
3
5
4
NOTE:
1. Conne
ct positive DC line to the ‘+’ terminal
and the DC
ground to the ‘-’ terminal.
2. When downloading project using a USB
cable, do not connect HMI with PLC and PC
simultaneously, for electric potential difference
may result in damage to HMI or PC.
(A)
(B)
Cutout
(1) Installation Instruction, 2-sided A4 *1
(2) Human Machine Interface *1
(3) Power Connector *1
(4) Brackets & Screws *1 pack
(1)
(2)
(3)
(5)
(4)
(5) Fuse 1.25A/250V 5*20mm *1
1