background image

 

 
 
 
 
 
 
 

 

Installation and Startup Guide

 

This document covers the installation of cMT2108X Series HMI, for the detailed specifications and 
operation, please refer to Datasheet, Brochure and EasyBuilder Pro User Manual. Please read all 
warnings, precautions, and instructions on the device carefully before use. 

Install Environment: 

NEMA Rating

 

The HMI product is NEMA 4 rated, indoor use only.

 

Electrical 
Environment

 

The 

HMI product has been tested to conform to European CE requirements. This 

means that the circuitry is designed to resist the effects of electrical noise. This 
does not guarantee noise immunity in severe cases. Proper wire routing and 
grounding will insure proper operation.

 

Environmental 
Considerations

 

(1)  Make sure that the displays are installed correctly and that the operating 

limits are followed. Avoid installing units in environments where severe 
mechanical vibration or shocks are present. 

(2)  Do not operate the unit in areas subject to explosion hazards due to 

flammable gases, vapors or dusts.

 

(3)  Do not install the unit where acid gas, such as SO2 exists. 
(4)  This device should be mounted in the vertical position and for use on the flat 

surface enclosure.

 

(5)  Relative Humidity: 10% ~ 90% (non-condensing)

 

Cleaning 
Considerations 

Clean the device using dry cloths. Do not use liquid or spray detergents for 
cleaning. 

IP Rating 

IP 66 

 
Warning 

Protection impairment if used in a manner not specified by the manufacturer. 
Déficit de protection si utilisé d'une manière non spécifiée par le fabricant. 

Unpacking the Unit

 

Unpack and check the delivery. If damage is found, please contact the supplier.

 

 

NOTE: 

Place the operator panel on a stable surface during installation. Dropping it or letting it 

fall may cause damage. 

The package includes: 
(1) Installation Instruction, 2-sided A4 *1 (2) Human Machine Interface *1 (3) Power Connector *1 
(4) Brackets & Screws *1 pack (5) USB Stick Clamp & Tying Strap *1 
 

Installation Instructions

 

Use a control box that provides enough stiffness. Cutout 
Dimension: 260 mm x 202 mm. Secure the operator 
panel in position, using all the fastening holes and the 
provided brackets and screws. Screw Torque: 2.6 ~ 3.9 
lbf.in. (For reaching waterproof effect and preventing the 
panel from being deformed.) 
Plan for adequate space around the unit and inside the 
enclosure, for ventilation and cables. Consider the heat 

from other devices inside the enclosure. The ambient temperature around the unit must be 0 ~ 50°C 
Minimum required clearances (along the overlay): Top / Bottom / Sides 15 mm 
Maximum panel thickness: 4.5 mm 
The aluminum flat-sheet at the back of the unit is a heat sink. Please be careful not to touch the heat 
sink since its heat can rise to 70°C in maximum when the unit is running. Planning for a 3cm space 
between the back of the unit and other devices is recommended. 

 
USB Stick Clamp Usage 

Combining the USB Stick with the clamp and the tying strap can prevent USB stick from disconnecting 
with HMI when strong vibration is present. 
1. Insert the USB connector to the clamp and tie them together with the tying strap. 
2. Press the spring and insert the USB stick into HMI. 

   

 
 
 
 
 
 

 

Power Connections 

 

Power Connector Specifications:   
Wire AWG: 24~12 
Wiring Conductor Minimum Temperature: 75°C 
Screw Torque: 4.5 lbf-in (max.) 
Copper conduct only.

 

Spécifications du connecteur d'alimentation: 
AWG de fil: 24 ~ 12 
Température minimale du conducteur de câblage: 75°C 
Couple de vis: 4.5 lbf-in (max.) 
Conducteur en cuivre seulement

 

NOTE:   

1. Connect positive DC line to the ‘+’ terminal and the DC ground to the 
‘-’ terminal. 
2. When downloading project using a USB cable, do not connect HMI 
with PLC and PC simultaneously, for electric potential difference may 
result in damage to HMI or PC.

   

 

System Settings 

When HMI is powered up and displays image, press 
the round Start Button in the upper-left corner of the 
screen to open the Setting dialog box. Tap the lock 
icon 

  and log in. (Default System Password: 

111111) 
Go to the Network tab, and setup your network. 
In Setting dialog box you can see device information, 
configure general settings, set HMI Time/Date/Name, 
and more.

 

 

 
 
 
 
 
 
 

 

cMT2108X series

 

                                                                                                               