上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD
.
9
/
116
3. Configure the devices based on your demands:
o
To add a controller/terminal board, right-click on
BusO
and select
Add
controller
and select the target controller/terminal board.
o
To replace a controller/terminal board, right-click on the controller/terminal
board to be replaced and click
Replace
. Select the target controller/terminal
board in the displayed list.
o
To delete a controller/terminal board, right-click on the controller/terminal
board to be deleted and click
Delete
.
o
To move a controller/terminal board, click the controller/terminal board to be
moved and click
Up/Down
.
4. Save the change by clicking
or
.
Follow the steps below to configure port mapping:
1. In the left column, click the
Configuration
tab. Go to
NcStudio
>
Hardware
Connection and Configuration
>
Port Mapping
.
2. Double-click
Port Mapping
to open the
Port Mapping
window to the right.
3. In the port list:
o
To show only a certain type of ports, click the category on the left, such as
Lubricate
.
o
To modify the physical address of a logical address, double-click the
corresponding physical address box and select the target controller and port.
o
To show/hide the logical addresses, right-click on the
Enter
/
Output
list and
select
Display logical address/Hide logical address
.
o
To delete a port mapping, right-click on the
Enter
/
Output
list and select
Delete port mapping
.
o
To delete invalid port mapping, right-click on the
Enter
/
Output
list and select
Delete invalid port mapping
.
3.2.4 Port Protection
When the software is closed, the protected ports will be automatically closed, opened,
following the status of the specified port, or reversed based on their port protection type.
There are several types of port protection:
Open
: The port will be automatically opened when the software is closed.
Closure
: The port will be automatically closed when the software is closed.
Follow
: The protected port status will be turned the same with that of the port
specified in the
Follow port
column.
Reverse
: The protected port status will be turned the opposite to that of the port
specified in the
Follow port
column.
Follow the steps below to set port protection:
1. In the left
Configuration
list, double-click
Port Protect
to open the
Port Protect
window to the right:
Summary of Contents for LS6000M
Page 75: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 72 116 With brake lines 50P HD plug...
Page 76: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 73 116 Without brake lines 50P HD plug...
Page 78: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 75 116 One to two...
Page 81: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 78 116 Fuji alpha5 plus axis X Y1 Y2...
Page 83: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 80 116 Delta ASDA B...
Page 84: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 81 116 Delta ASDA B one to two...
Page 86: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 83 116 MR JE with brake cable...
Page 87: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 84 116...
Page 91: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 88 116 ESDA...
Page 93: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 90 116 R series...
Page 96: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 93 116 With brake lines 50P HD plug...
Page 97: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 94 116 Without brake lines 44P interface...
Page 105: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 102 116 Delta ASDA B2...
Page 112: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 109 116 The button definitions are shown below...
Page 114: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 111 116 The button definitions are shown below...
Page 115: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 112 116...
Page 117: ...SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO LTD 114 116...