![Weidmüller 1253240000 Manual Download Page 12](http://html1.mh-extra.com/html/weidmuller/1253240000/1253240000_manual_952350012.webp)
Installation and Connectors
12
1253240000/00/02.11
3.3
Data connection
The FreeCon Active PROFINET-POF-Repeater has two 100BaseFX Ethernet ports for polymer optical fibre
(POF). These SC-type fibre ports are fairly straightforward to connect since optical-fibre connections do not
require the circuit needed for electrical signals.
One of the optical lines is used to transmit data from device I to device II, and the other optical line is used
transmit data from device II to device I, for full-duplex transmission. Remember to connect the Tx (transmit)
port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit)
port of device II, as shown in the illustration below.
Rx
Tx Rx
Tx
DEVICE 1
REPEATER
DEVICE 2
Tx
Rx Tx
Rx
Figure 5
Rx-to-Tx cabling between the device and the FreeCon Active PROFINET-POF-Repeater
Use Weidmüller’s PushPull
STEADYTEC
®
data plug: the IE-PS-V14M-2SC-POF (order number
1191550000).
Figure 6
The IE-PS-V14M-2SC-POF data plug
WARNING
This is a Class 1 Laser/LED product. To avoid causing serious damage to your eyes, do not stare
directly into the Laser Beam.
3.4
Grounding/earthing
Proper earthing and wire routing are important in order to limit the effects of electromagnetic interference
(EMI).The earthing on the FreeCon Active PROFINET-POF-Repeater is established using the functional
earth from the power plug.