background image

 
 
 
 
 

Ethernet Switch 

– Premium Line

 

IE-SW-PL18M Series (Managed) 

 

Hardware Installation Guide 

 
 
 
 

Fourth Edition, October 2012 

1243410000/03/10.12 

 
 
 

Please note: 

This document, the 

detailed manual

 and any further 

product information - if available - can be 

downloaded at the internet link: 

 

http://www.weidmueller.com/downloads

 

 
 
 
 
 
 

Copyright Notice 

Copyright   2012 Weidmüller Interface GmbH & Co. KG 

All rights reserved. 

Reproduction without permission is prohibited. 

 
 
 
 

 

Summary of Contents for IE-SW-PL18M Series

Page 1: ...3410000 03 10 12 Please note This document the detailed manual and any further product information if available can be downloaded at the internet link http www weidmueller com downloads Copyright Noti...

Page 2: ...PL18M Hardware Installation Guide CD ROM with User s Manual and Windows Utility option Please download CD ROM from Internet page http www weidmueller com downloads RJ45 to DB9 Console port cable Prote...

Page 3: ...or PWR1 Relay 1 and Relay 2 6 10 100BaseT X ports 1 to 16 7 PWR 1 LED for power input 1 8 PWR 2 LED for power input 2 9 Fault LED 10 MSTR HEAD LED 11 CPLR TAIL LED 12 10 100 1000BaseT X port G2 13 10...

Page 4: ...ces 4 6 pin terminal block for DI 1 DI 2 and PWR 2 5 6 pin terminal block for PWR1 Relay 1 and Relay 2 6 10 100BaseT X ports 1 to 14 7 PWR 1 LED for power input 1 8 PWR 2 LED for power input 2 9 Fault...

Page 5: ...the DIN Rail attachment plate to IE SW PL18M make sure the stiff metal spring is situated towards the top as shown by the following figures STEP 1 Insert the top of the DIN Rail into the slot just bel...

Page 6: ...r has been switched off or the area is known to be non hazardous The devices may only be connected to the supply voltage shown on the type plate The devices are designed for operation with a Safety Ex...

Page 7: ...ctromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices ATTENTION This product is intended to be mounted to a well grounded m...

Page 8: ...s The top and front views of one of the terminal block connectors are shown here STEP 1 Insert the negative ground positive DI wires into the I1 terminals respectively STEP 2 To keep the DI wires from...

Page 9: ...d DB25 connectors and hole numbers for female DB9 and DB25 connectors are labeled on the connector However the numbers are typically quite small so you may need to use a magnifying glass to see the nu...

Page 10: ...MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch ty...

Page 11: ...d II As opposed to electrical signals optical signals do not require a circuit in order to transmit data Consequently one of the optical lines is used to transmit data from device I to device II and t...

Page 12: ...ed and a user configured event is not triggered or when the corresponding PORT alarm is disabled MSTR HEAD GREEN On When the switch is set as the Master of the Turbo Ring or as the Head of the Turbo C...

Page 13: ...h LACP Protocols IGMPv1 v2 GMRP GVRP SNMPv1 v2c v3 DHCP Server Client DHCP Option 66 67 82 BootP TFTP SNTP SMTP RARP RMON HTTP HTTPS Telnet SSH Syslog IPv6 LLDP IEEE 1588 PTP Modbus TCP SNMP Inform MI...

Page 14: ...Tx 9 dBm 9 dBm 8 dBm 8 dBm Rx Sensitivity 21 dBm 21 dBm 23 dBm 23 dBm Link Budget 12 dB 12 dB 15 dB 15 dB Typical Distance 10 km 10 km 20 km 20 km Saturation 1 dBm 1 dBm 1 dBm 1 dBm a 50 125 m 400 MH...

Page 15: ...ted at the time when the risk passed will be repaired by Weidm ller free of charge or that Weidm ller will provide a new functionally equivalent product to replace the defective one Safe where express...