The following maintenance work may be carried out by the operator:
9�4�1
Replacing the wire filter insert (Pos� 3)
Î
Unscrew the filter from your system.
Î
Clamp the filter at the
wrench flat of the
outlet housing (Pos. 1) in a
vice.
Î
Unscrew the
inlet housing (Pos. 2)
out off the
outlet housing (Pos. 1) using
a rolling fork wrench.
Î
Unscrew the
wire filter insert (Pos. 3)
using the hexagonal allen key
A/F6 and remove it from the
outlet housing (Pos. 1).
Î
Remove the O-ring and the
back-up ring with the
WEH
®
O-ring picker.
MD-10012-L51-R1.1.0-03
Page 20
Operating instructions
AE
Summary of Contents for TSF4