5
DETAILED PARAMETER DESCRIPTION
✓
NOTE!
This parameter can be changed only with the motor stopped.
P0401 - Motor rated current
Adjustable range:
0.1 to 3705.0 A
Factory setting:
140.0 A
Acesso:
Menu
→
Configurations
→
Nominal data
→
Motor
Description:
Set according to the motor nameplate data, taking into account the motor voltage.
✓
NOTE!
This parameter can be changed only with the motor stopped.
P0402 - Motor rated speed
Adjustable range:
1 to 7200 rpm
Factory setting:
1796 rpm
Acesso:
Menu
→
Configurations
→
Nominal data
→
Motor
Description:
Set this parameter according to the motor nameplate data.
The range for V/F is from 0 to 7200 rpm.
✓
NOTE!
This parameter can be changed only with the motor stopped.
P0403 - Motor Rated Freq
Adjustable range:
1 to 120 Hz
Factory setting:
60 Hz
Acesso:
Menu
→
Configurations
→
Nominal data
→
Motor
Description:
Set this parameter according to the motor nameplate data.
The range for V/F is from 1 to 120 Hz.
✓
NOTE!
This parameter can be changed only with the motor stopped.
P0405 - Speed sensor data (encoder)
Adjustable range:
100 to 9999 PPR
Factory setting:
1024 PPR
Acesso:
Menu
→
Configurations
→
Nominal data
→
Motor
Description:
Program the number of pulses per revolution (ppr) of the used incremental encoder when P0202 = 4 (Vector
with Encoder).