Basic Instructions for Programming and Settings
5-6 | CFW501
5
P0216 – HMI Display Light
Adjustable
Range:
0 = Inactive
1 = Active
Factory
Setting:
1
Properties:
Access groups
via HMI:
HMI
Description:
The function of this parameter is to turn on or off the backlight of the HMI display.
NOTE!
When the remote HMI is connected and activated by P0312, the light of the CFW501 local HMI is
cut off and parameter P0216 starts to control the remote HMI.
5.4 INDIRECT ENGINEERING UNITS
This parameter group allows the user to configure the engineering units for the user's parameters of the SoftPLC
function.
P0510 – Indirect Engineering Unit 1
Adjustable
Range:
0 = none
1 = V
2 = A
3 = rpm
4 = s
5 = ms
6 = none
7 = m
8 = none
9 = none
10 = %
11 = °C
12 = none
13 = Hz
14 = none
15 = h
16 = W
17 = kW
18 = none
19 = none
20 = min
21 = °F
22 = bar
23 = mbar
24 = psi
25 = Pa
26 = kPa
27 = MPa
28 = mwc (meter of water column)
29 = mca (metro de coluna d'água)
30 = gal
31 = l (litro)
32 = in
33 = ft
34 = m³
35 = ft³
36 = gal/s
37 = gal/min (= GPM)
Factory
Setting:
22
Summary of Contents for CFW501 V1.8X
Page 2: ......
Page 8: ...Summary...
Page 34: ...General Information 2 4 CFW501 2...
Page 38: ...About the CFW501 3 4 CFW501 3...
Page 42: ...HMI and Basic Programming 4 4 CFW501 4...
Page 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Page 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Page 76: ...Available Motor Control Types 8 4 CFW501 8...
Page 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Page 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Page 148: ...Faults and Alarms 14 12 CFW501 14...