Programming Basic Instructions
5-10
5
5.6 DISPLAY INDICATIONS IN THE MONITORING MODE SETTINGS
Every time the inverter is powered the display goes to the Monitoring Mode. In order to make it easier the reading
of the motor main parameters, the keypad (HMI) display can be configured to show them in 3 different modes.
Content of the 3 parameters in numerical form:
Selection of the parameters via P0205, P0206 and P0207. That mode can be seen in the
.
Run
LOC
1800rpm
12:35
Menu
1800
rpm
1.0
A
60.0
Hz
Inverter indications:
- Run
- Ready
- Configuration
- Self tuning
- Last fault: FXXX
- Last alarm: AXXX
- DC Braking
- STO
Motor speed direction
indication.
Loc./Rem. indication
- LOC: Local situation.
- REM: Remote situation.
Motor speed indication
in rpm.
Monitoring parameters:
- Motor speed in rpm.
- Motor current in Amps;
- Output frequency in Hz (default).
P0205, P0206 and P0207: selection of the
parameters to be shown in the Monitoring Mode.
P0208 to P0212: Engineering unit for the speed
indication.
Right "soft key" function.
Indication of the time.
Adjusted in:
P0197, P0198 and P0199.
Left "soft key" function.
Figure 5.3 -
Monitoring Mode screen at the factory setting
Content of the 3 parameters in form of a bar graph:
Selection of the parameters via P0205, P0206 and/or P0207. The values are showed in percentage by means
of horizontal bars. This mode is illustrated in the
.
Run
LOC
1800rpm
12:35
Menu
rpm
A
Hz
Monitoring parameters:
- Motor speed in rpm.
- Motor current in Amps.
- Output frequency in Hz (default).
P0205, P0206 and P0207: selection of the parameters
to be shown in the Monitoring Mode.
P0208 to P0212: Engineering unit for the speed indication.
100%
10%
100%
Figure 5.4 -
Monitoring Mode screen with bar graphs
In order to configure the bar graph monitoring mode, access the parameters P0205, P0206 and/or P0207 and
select the options ended with the symbol "–" (values in the range from 11 to 20). Thus, the respective variable
is configured to be shown as a bar graph.
The
, presented next, illustrates the procedure for the modification of the display of
one variable to the graph mode.
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...