11-13
11
Vector Control
Table 11.1 -
P0404 (Motor Rated Power) setting
P0404
Motor Rated
Power (hp)
P0404
Motor Rated
Power (hp)
0
0.33
31
300.0
1
0.50
32
350.0
2
0.75
33
380.0
3
1.0
34
400.0
4
1.5
35
430.0
5
2.0
36
440.0
6
3.0
37
450.0
7
4.0
38
475.0
8
5.0
39
500.0
9
5.5
40
540.0
10
6.0
41
600.0
11
7.5
42
620.0
12
10.0
43
670.0
13
12.5
44
700.0
14
15.0
45
760.0
15
20.0
46
800.0
16
25.0
47
850.0
17
30.0
48
900.0
18
40.0
49
1000.0
19
50.0
50
1100.0
20
60.0
51
1250.0
21
75.0
52
1400.0
22
100.0
53
1500.0
23
125.0
54
1600.0
24
150.0
55
1800.0
25
175.0
56
2000.0
26
180.0
57
2300.0
27
200.0
58
2500.0
28
220.0
59
2900.0
29
250.0
60
3400.0
30
270.0
-
-
NOTE!
When adjusted via keypad (HMI), this parameter may change the parameter P0329 automatically.
Refer to the
Item 12.7.2 Vector Flying Start on page 12-12
P0405 – Number of Encoder Pulses
Adjustable
Range:
100 to 9999 ppr
Factory
Setting:
1024 ppr
Properties:
CFG
Access groups
via HMI:
01 PARAMETER GROUPS
43 Motor Data
Description:
It sets the number of pulses per rotation (ppr) of the used incremental encoder.
Summary of Contents for CFW-11 Series
Page 2: ......
Page 54: ...2 4 2 General Information ...
Page 58: ...About the CFW 11 3 3 4 ...
Page 74: ...Inverter Model and Accessories Identification 5 14 6 ...
Page 86: ...Inverter Model and Accessories Identification 6 12 6 ...
Page 94: ...Available Control Types 8 2 8 ...
Page 118: ...VVW Control 10 8 10 ...
Page 182: ...Functions Common to All the Control Modes 12 26 12 ...
Page 220: ...Dynamic Braking 14 4 14 ...