Tabel A.4:
Technische specificatie voor 660 tot 690 Vac, driefase netvoeding
M
o
de
l
Framemaat
G
eb
ru
ik m
et n
o
rm
al
e (
N
D
) c
yc
lu
s
G
eb
ru
ik m
et Z
w
ar
e (
N
D
) C
yc
lu
s
Omgevingsluchttemperatuur
Ingebouwde Dynamisch
Remsysteem
Ingebouwd Categorie C3
RFi-filter
Gewicht [kg]
Nominale Uitgangsstroom
[Arms]
(1)
O
ve
rb
el
as
ti
ng
S
tr
oom
[A
rms
]
(2
)
Schakelfrequnetie [kHz]
(1) (4)
Maximale Motor
[HP/kW]
(5)
Nominale Ingangsstroom
[Arms]
G
ed
is
si
p
ee
rd
V
er
m
o
ge
n
[W
]
(3
)
Nominale Uitgangsstroom
[Arms]
(1)
O
ve
rb
el
as
ti
ng
ss
tr
o
o
m
[Arm
s]
(2
)
Schakelfrequnetie [kHz]
(1)
(4)
Maximale Motor
[HP/kW]
(5)
Nominale
Ingangsstroom [Arms]
G
ed
es
si
n
ee
rd
V
er
m
o
ge
n
[W
]
(3
)
1 m
in
3 s
O
pp
er
vl
ak
te
m
on
ta
g
e
F
le
n
sm
o
nt
ag
e
1 m
in
3 s
O
pp
er
vl
ak
te
m
on
ta
g
e
F
le
n
sm
o
nt
ag
e
C
FW
11
000
2T
6
D
2.
9
3.
2
4.
4
5
2/
1.
5
2.
9
11
9
60
2.7
4.1
5.4
5
1.
5/
1.
1
2.7
11
4
60
-10...50 °C
(14...122 °F)
Ja, behalve in modellen CFW11...O.…NB...
Ja, behalve in modellen CFW11...O.…NF...
34/75
C
FW
11
000
4T
6
D
4.
2
4.
6
6.
3
5
3/
2.
2
4.
2
14
9
65
3.
8
5.7
7.
6
5
2/
1.
5
3.
8
14
0
63
C
FW
11
000
7T
6
D
7.
0
7.
7
10
.5
5
5/
3.
7
7
216
75
6.5
9.
8
13
.0
5
3/
2.
2
6.5
20
4
73
C
FW
11
0
01
0T
6
D
8.5
9.4
12
.8
5
7.5
/5
.5
8.5
251
80
7.
0
10
.5
14
.0
5
5/
3.
7
7
216
75
C
FW
11
0
01
2T
6
D
11
12
.1
16.5
5
10
/7.
5
11
31
0
89
9.
0
13
.5
18
.0
5
7.5
/5
.5
9
26
3
82
C
FW
11
0
01
7T
6
D
15
16.5
22.
5
5
15
/11
15
40
5
10
3
13
19
.5
26
.0
5
10
/7.
5
13
358
96
C
FW
11
0
02
2T
6
D
20
22.
0
30
.0
5
20/
15
20
52
3
12
1
17
25
.5
34.
0
5
15
/11
17
452
11
0
C
FW
11
0
02
7T
6
D
24
26
.4
36
.0
5
25
/18
.5
24
618
13
5
20
30
.0
40
.0
5
20/
15
20
52
3
12
1
C
FW
11
0
03
2T
6
D
30
33
.0
45
.0
5
30
/2
2
30
76
0
15
6
24
36
.0
48
.0
5
25
/18
.5
24
618
13
5
C
FW
11
0
04
4T
6
D
35
38
.5
52.
5
5
40
/3
0
35
878
174
30
45
.0
60
.0
5
30
/2
2
30
76
0
15
6
C
FW
11
0
05
3T
6
E
46
50
.6
69.
0
2
50
/37
46
911
19
6
39
58
.5
78
.0
2
40
/3
0
39
78
3
17
7
-10...45 °C
(13...104 °F)
Ja
64/141
C
FW
11
0
06
3T
6
E
54
59
.4
81.
0
2
60
/4
5
54
10
57
218
46
69.
0
92.
0
2
50
/37
46
911
19
6
C
FW
11
0
080
T6
E
73
80.
3
10
9.
5
2
75
/5
5
73
14
05
270
61
91.
5
12
2.
0
2
75
/5
5
61
11
85
237
C
FW
11
01
07
T6
E
10
0
11
0.
0
15
0.
0
2
12
5/
90
10
0
18
99
34
4
85
12
7.
5
17
0.
0
2
10
0/
75
85
16
24
303
CF
W
11
01
25T
6
E
10
8
11
8.
8
16
2.
0
2
12
5/
90
10
8
20
45
36
6
95
14
2.
5
19
0.
0
2
12
5/
90
95
18
07
331
C
FW
11
01
50
T6
E
13
0
14
3.
0
19
5.
0
2
15
0/
11
0
13
0
24
47
427
10
8
16
2.
0
216
.0
2
12
5/
90
10
8
20
45
36
6
C
FW
11
01
70
T6
F
14
7
16
1.
7
22
0.
5
2
17
5/
132
14
7
28
38
10
91
12
7
19
0.
5
25
4.
0
2
15
0/
11
0
12
7
247
2
963
Nee
168/371
C
FW
11
02
16
T6
F
19
5
214
.5
29
2.
5
2
20
0/
16
0
19
5
371
6
13
98
16
5
24
7.
5
33
0.0
2
15
0/
13
2
16
5
316
7
12
06
C
FW
11
02
89
T6
F
25
9
28
4.
9
38
8.5
2
25
0/
20
0
25
9
48
86
1808
225
33
7.
5
45
0.0
2
20
0/
16
0
225
42
64
15
90
CF
W
11
03
15T
6
G
25
9
28
4.
9
38
8.5
2
30
0/
220
25
9
49
36
18
58
225
33
7.
5
45
0.0
2
25
0/
20
0
225
43
14
16
40
258/569
CF
W
11
03
65T
6
G
312
343
.2
46
8.0
2
350
/2
50
312
59
05
219
7
25
9
38
8.5
51
8.
0
2
30
0/
220
25
9
49
36
18
58
CF
W
11
04
35T
6
G
36
5
40
1.
5
54
7.
5
2
40
0/
315
36
5
68
74
25
36
312
46
8.0
624
.0
2
350
/2
50
312
59
05
219
7
C
FW
11
04
72
T6
G
427
46
9.7
64
0.
5
2
50
0/
370
427
80
42
29
67
36
5
54
7.
5
73
0.
0
2
400
/3
00
36
5
69
08
25
70
C
FW
11
05
84
T6
H
47
8
52
6
717
2
60
0/4
40
47
8
914
0
338
2
41
0
615
820
2
50
0/
370
41
0
78
40
29
01
-10...40 °C
(14...104 °F)
200
CF
W
11
06
25T
6
H
51
8
570
777
2
65
0/4
80
51
8
99
05
36
65
447
671
894
2
60
0/4
40
447
85
47
316
3
C
FW
11
07
58
T6
H
628
69
0.
8
942
2
80
0/5
90
628
12
0
09
444
3
51
8
777
10
36
2
65
0/4
80
51
8
99
05
36
65
213
C
FW
11
080
4T
6
H
70
3
773
10
55
2
90
0/
690
70
3
134
43
49
74
59
4
89
1
11
88
2
75
0/
56
0
59
4
11
35
8
42
03
(1)
Stabiele toestand nominale stroom onder de volgende voorwaarden:
- Aangegeven schakelfrequentie of lager. Voor hogere schakelfrequentie raadpleegt u WEG.
- Modellen van framemaat E, F, G en H mogen niet worden gebruikt bij een schakelfrequentie van 10 kHz.
- Omgevingsluchttemperatuur wordt in tabellen vermeld. Van 40ºC tot 45ºC (104ºF tot 113ºF) voor framemaat H: 1% van stroomreductie voor elke graad Celsius boven de maximum temperatuur, zoals
aangegeven in het onderdeel hierboven. Van 50ºC tot 60ºC (122°F tot 140°F) voor framematen B, C en D modellen en van 45ºC tot 55ºC (113ºF tot 131ºF) voor framematen E, F, G en H modellen: 2 % van
stroomreductie voor elke graad Celsius boven de maximum temperatuur, zoals aangegeven in het onderdeel hierboven.
- Relatieve luchtvochtigheid 5% tot 95% niet condenserend.
- Hoogte: 1000 m. Boven 1000 m tot 4000 m moet de uitgangsstroom worden gereduceerd met 1% voor elke 100 m boven 1000 m.
- Omgeving met vervuilingsgraad 2 (volgens EN50178 en UL508C).
(2)
Elke 10 minuten een overbelasting.
(3)
De informatie die verstrekt wordt over de inverterverliezen is geldig voor de nominale exploitatieomstandigheden, d.w.z. voor nominale uitgangsstroom en nominale schakelfrequentie.
(4)
Alleen voor framematen B, C en D: de schakelfrequentie kan automatisch verminderd worden tot 2.5 kHz afhankelijk van de exploitatieomstandigheden (omgevingsluchttemperatuur, uitgangsstroom
etc.) - als P0350 = 0 of 1.
Als er altijd met 5 kHz gewerkt moet worden, stelt u P0350 = 2 of 3 in en reduceert u de uitgangsstroom. Zie WEG voor meer informatie.
(5)
De motorvermogens zijn slechts een richtlijn, uitgaande van 575 V, 60 Hz voor netvoeding van 500 tot 600 Vac of 690 V, 50 Hz voor netvoeding 660 tot 690 Vac, WEG 4-polige motoren. De adequate
inverterafstelling moet gebaseerd zijn op de gebruikte nominale motorstroom.