Maintenance | 4

3398336D OI FS 2500

5 / 8

4

Maintenance

CAUTION

Cleaning agents may contain harmful components

Damage to the product.

u

Never use solvents such as:

-

Alkaline products containing sodium solutions

-

Methylated spirits

-

Muriatic acid or products containing phosphor

-

Turpentine

-

White spirit

-

Window cleaning products

CAUTION

Dry materials can damage the shading system

u

Never rub the dry surface of the shading system.

u

Never use steel wool, abrasives or sandpaper.

CAUTION

High-pressure cleaners can damage the shading
system

u

Never use a high-pressure cleaner to clean the shad-
ing system.

Regular maintenance of the shading system makes cleaning
easier and ensures smooth operation.
Clean and check the functioning of the drainage system regu-
larly by pouring water into the gutters. The water should drain
off quickly.

4.1

Cleaning

1.

Wash the shading system with clean, lukewarm water and
a soft brush.

2.

Dry the fabric in the open air.

In case of stubborn stains:

1.

Use a mild soap or Tex Activ Cleaner, dissolved in lukewarm
water.

2.

Rinse the fabric with clean water.

3.

Dry the fabric in the open air.

4.

Make the fabric water repellent again after using Tex Activ
Cleaner.

4.2

Greasing

Fig. 4 Cleaning and greasing

1.

Clean the inside of the guides.

2.

Apply a thin layer of grease (Isoflex® Topas L32) to the in-
side of the guides.

4.3

Tensioning the outer fabric

WMS000242A

1

2

3

4

Fig. 5 Tensioning fabric

1.

Close the folding shade completely.

2.

Locate the tensioning bolts:

– The tensioning bolt (1) is in the rear shoe (2) on the left

and right guides (3) at the rear of the folding shade, and
near the drive tubes (4).

3.

To stretch the outer fabric and remove any wrinkles or
folds, evenly tighten the tensioning bolts (1) for the left and
right guide.

5

Troubleshooting

Symptom

Possible cause

Possible solution

The FS 2500 does
not open / close.

No power or low
power.

Check the battery.

Blown fuse / tripped
circuit breaker.

Replace fuse / reset
circuit breaker.

Motor does not op-
erate properly.

Open or close the
FS 2500 manually in
accordance with the
manual operation
procedure.

Switch does not op-
erate properly.

Check wiring.
Replace switch.

Poor opening / clos-
ing of the FS 2500.

Polluted guides.

Clean the inside of
the guides.
Apply a thin layer of
grease to the inside
of the guides.

The FS 2500 still
does not open /
close smoothly after
cleaning / greasing.

Contact your dealer
for maintenance
and / or repair.

Fabric is folded /
wrinkled when the
FS 2500 is closed.

Tighten the tension-
ing bolts to stretch
the fabric.

Initialization not
possible.

Low power at mo-
tor

Check your battery.
Increase the thick-
ness of the power
supply wires

Summary of Contents for FS 2500

Page 1: ...Operating Instructions Marine Shading Systems FS 2500 English...

Page 2: ...view of the folding shade 4 3 2 Opening the folding shade 4 3 3 Closing the folding shade 4 4 Maintenance 5 4 1 Cleaning 5 4 2 Greasing 5 4 3 Tensioning the outer fabric 5 5 Troubleshooting 5 6 Manual...

Page 3: ...d operating in structions This liability exclusion particularly applies to l Installation by untrained personnel l Improper use l Repairs not carried out by a Webasto service workshop l Use of non gen...

Page 4: ...ompletely 2 Optionally briefly pushing the Open button again stops the opening movement 3 3 Closing the folding shade 3 3 1 Closing the folding shade WMS000190A Fig 3 Closing the folding shade The FS...

Page 5: ...and greasing 1 Clean the inside of the guides 2 Apply a thin layer of grease Isoflex Topas L32 to the in side of the guides 4 3 Tensioning the outer fabric WMS000242A 1 2 3 4 Fig 5 Tensioning fabric 1...

Page 6: ...the steps in chapter 6 3 Reinitializing the control system on page 7Table Reinitial izing the control system on page 7 6 2 Manually moving the folding shade over more than 25 cm 1 In case the FS 2500...

Page 7: ...slides in small steps until completely closed The motor produces a loud click sound 4 Release the Close button The control system has been initialized 5 Open close the FS 2500 several times 6 Verify...

Page 8: ...ebasto com 3398336D Europe Asia Pacific Webasto Thermo Comfort SE Postfach 1410 82199 Gilching Germany Company address Friedrichshafener Str 9 82205 Gilching Germany UK only Webasto Thermo Comfort UK...