2.4 Glow Plug
The mixture of fuel and air is ignited by the glow plug when the heater is started. The glow plug designed as an electrical
resistor is positioned in the burner assembly (evaporator mount with combustion pipe) on the side facing the flame.
Figure 7: Glow Plug
2.5 Exhaust Temperature Sensor
The exhaust temperature sensor is a low-resistance PTC resistor which changes its resistance in dependence on the
temperature change of the exhaust gases. This change in resistance is also used for flame monitoring.
Figure 8: Exhaust Temperature Sensor