background image

3

Installation

The product must be installed and maintained by a 

VXLWDEO\TXDOLƂHGSURIHVVLRQDOLQFRPSOLDQFHZLWKODWHVW

 

building/construction and/or electrical regulations and 

relevant legislation.

Warning:

 Switch off mains electrical supply prior to 

installing and connecting the luminaire.

Notice:

,IWKHOXPLQDLUHLVPRGLƂHGE\DQ\ERG\RWKHU

than the original manufacturer, then the warranty will 

no longer be valid and shall become the full respon-

sibility of the modifying person/organisation. Claims 

based on defects attributable to improper installation 

and/or application, and the consequences thereof, are 

excluded.

Installation Procedure

1)  Prior to electrical connection, proceed with mechan-

ical installation by securing stirrup 

B

 to optional 

mounting accessory or directly to a suitable surface 

with bolts 

D

. Aim luminaire in the desired direction.

 

Warning:

 Ensure not to damage any electric cable, 

water pipe or other devices while drilling holes.

2)  Switch off mains electrical supply.

3)  Check that rating shown on luminaire label  

conforms with mains electrical supply.

4)  Trim the cable 

A

 to the desired length and connect 

the leads to their respective terminals at the base of 

the pole: (L = Phase, N = Neutral,   = Earthing).

5)  To aim luminaire: Loosen screws 

C

 slightly, adjust 

aiming then tighten screws 

C

. Tighten screw 

E

 to  

secure orientation of luminaire.

Reviews: