3
Installation
The product must be installed and maintained by a
VXLWDEO\TXDOLƂHGSURIHVVLRQDOLQFRPSOLDQFHZLWKODWHVW
building/construction and/or electrical regulations and
relevant legislation.
Warning:
Switch off mains electrical supply prior to
installing and connecting the luminaire.
Notice:
,IWKHOXPLQDLUHLVPRGLƂHGE\DQ\ERG\RWKHU
than the original manufacturer, then the warranty will
no longer be valid and shall become the full respon-
sibility of the modifying person/organisation. Claims
based on defects attributable to improper installation
and/or application, and the consequences thereof, are
excluded.
Installation Procedure
1) Prior to electrical connection, proceed with mechan-
ical installation by securing stirrup
B
to optional
mounting accessory or directly to a suitable surface
with bolts
D
. Aim luminaire in the desired direction.
Warning:
Ensure not to damage any electric cable,
water pipe or other devices while drilling holes.
2) Switch off mains electrical supply.
3) Check that rating shown on luminaire label
conforms with mains electrical supply.
4) Trim the cable
A
to the desired length and connect
the leads to their respective terminals at the base of
the pole: (L = Phase, N = Neutral, = Earthing).
5) To aim luminaire: Loosen screws
C
slightly, adjust
aiming then tighten screws
C
. Tighten screw
E
to
secure orientation of luminaire.