![WDT UP 35 Operating Instruction Download Page 41](http://html2.mh-extra.com/html/wdt/up-35/up-35_operating-instruction_4001330041.webp)
41 / 45
9.1.2
Monthly
Skin irritations due to contact with greases or oils.
Wear suitable protective gloves and goggles. Observe the safety instructions in the "Safety data
sheet" of the grease or oil.
Lubricate the crimping plunger via the grease nipple and
Grease the guide pins of the adapters with:
+
Blaser Swiss Lube Part-No. 00492-01 EP-Universal Grease,
+
Molykote DX Paste,
+
Dininol Grease LGM2, Part-No. 27620 (Gmelin GmbH & Co. KG).
+
Alternatively, lithium soap greases with the following application areas can be used:
o
sliding surfaces/friction contacts
o
high loads
o
non-soiling lubrication
o
low and medium speeds
o
base oil viscosity at 40°C (DIN 51562): 110mm²/s
9.1.3
After every 250.000 cycles or every two years
Maintenance work may only be carried out by authorized persons who have been trained for this
activity.
For inspections at the recommended intervals, please contact the manufacturer or dealer. The
service address can be found on page 2 of these operating instructions.
Please have the following information ready for the conversation:
+
Machine type
+
Serial number of the machine
CAUTION