7.1.2
Check / replace hose set
The pump hose in the pump is subject to mechanical and chemical stress. That is why the pump
hose must be checked 1 x a week to detect damages in due time
and to change the dosing hose.
The dosing hose must be changed at least every 6 months!
Components of the hose dosing pump
Figure 22, Hose dosing pump spare parts
Changing the hose set and roller carrier
see description in
Section 5.2 Commissioning work, "Insert roller carrier at the fragrance pump".
The hose pump Type Sa
31. Pump cover
32. Lock washer
33. Hose holder with dosing hose
34. Roller carrier
35. Pump housing
36. Sealing disk, felt
37. Sealing disk, EPDM
38. Geared motor
39. Installation screws