Brine fog maker, Type Solfog V2
Index: 01
Change date: 12/12/2017
Operating instructions no.: BA DW 018-01 Solfog V2 EN.docx
Page 27 of 39
7
Maintenance, service, faults
7.1
Device maintenance
It is recommended to task a specialist company with maintenance.
The following points must be considered for problem-free function of the Soldos:
1.
Disinfection and maintenance according to the maintenance protocol in Section
CAUTION !
Perform a disinfection each time the politainer is changed, however at least every 28
days! With a politainer of 5 kg, depending on the adjustment, a service time of appr.
15h is reached.
2.
Provisioning of the required consumables. Pay attention to durability and storage time!
3.
Regular cleaning of the device. Brine water causes dirty spots and attacks metals when it has not
been eliminated.
DANGER DUE TO HIGH VOLTAGE !
The device must be switched off and secured against re-operation before any electrical
work is carried out!
7.1.1
Maintenance works at the control casing general
ATTENTION !
The electronic components of the devices are sensitive to electrostatic discharge. The
generally known precautions regarding ESD-sensitive devices must be adhered to when
handling these devices!
Particularly for works at the control card:
Only pull or push in the plug-in connectors when they are not under tension.
Discharge your body for at least 5 seconds before you touch the devices, e.g. by touching a
grounded part of the system or by wearing an ESD ground strap that is connected to ground.
Connect the grounding connection (Pos.
) to the on-site grounding cable.
Open / close the housing
Unlock the locking button with a screw driver
Press onto both handle recesses until the housing clips open.
Swivel the lid sideways.
The housing is closed in reverse order
Figure 21, Open the control housing