Dosing unit GRANUDOS Type Flex-CPR Touch XL,
Type Flex-Touch and Type Flex-S5
Index: 01 Change date: 11/10/2023
OI No.: BA SW 022-01 Granudos Flex Dosiereinheit EN.docx
Page 59 of 68
d)
Attach the hose ends using the hose clamps and cut off the protruding ends of the hose clamps.
e)
Install hose bracket kit, see Chapter 5.2.1.
7.1.6
Cleaning the dust extraction (option)
CAUTION!
Due to the excessive chlorine dust, personal safety equipment must be put on prior to start-
ing the work: Protective gloves, apron, face protection.
Overview dust extraction
Procedure
a)
Remove, disassemble and clean the flushing ring (54) (see exploded drawing).
b)
Then reassemble the flushing ring. Ensure that the original screws are used again during reas-
sembly, since they are made of chloride-resistant material. Using other materials may cause
the screws to corrode.
Figure 46: Dust extraction