Dosing unit GRANUDOS Type Flex-CPR Touch XL,
Type Flex-Touch and Type Flex-S5
Index: 01 Change date: 11/10/2023
OI No.: BA SW 022-01 Granudos Flex Dosiereinheit EN.docx
Page 48 of 68
Overview flushing tub
Figure 37, GRANUDOS Flex dissolving unit
Key dissolving unit
Adjustment of suction capacity
The further procedure is only possible when the device is turned on.
a)
Switch on the device at the main switch.
The booster pump starts, unless the pressure switch (31) or the level switch min (48) respond.
b)
The hole washer in the pipe union (41) behind the injector (40) adjusts the injector’s suction
performance to the pressure conditions. If the water level in the flushing tub (39) drops during
commissioning, a hole washer with a smaller drill hole must be inserted in the pipe union.
c)
If the water level rises, or if the flow switch’s (42) switch body is not clearly pushed upwards,
a hole washer with a larger drill hole is required, or the hole washer must be removed entirely.
A hole washer with 6 mm is installed ex works; hole washers with 5.5 mm and 7 mm are available in
the enclosed spare parts bag.
31.
Pressure switch
32.
Pressure retention valve for supplying measuring
cell block (only CPR Touch XL)
33.
Outflow for supplying the measuring cell block
(only CPR Touch XL)
34.
Dirt filter d75 mm
35.
Flushing connection for dirt filter (option)
36.
Booster pump (different designs)
37.
---
38.
Flushing pipe
39.
Flushing tub
40.
Injector
41.
Pipe union with hole washer
42.
Flow switch for suction pipe
43.
Dosing valve for pH-reducer
44.
Dissolving and mixing cyclone
45.
Dust cover for booster pump
46.
Flushing tub overflow
47.
Floating valve inlet for flushing tub
48.
Level switch min/max for flushing tub
49.
Lid for flushing tub
50.
---