WDT Duftdos UNPL Operation Manual Download Page 3

 

 

Operation manual 20997-Duftdos-UNPL  (09/16)  

Page 3 von 9 

 

2.  

Saftey 

2.1  

Technical safety advice 

 

Company WDT does not take the liability for damages that occur due to not considering this manual. The easy and safe operation of the unit 

assumes a correct transport, storage and installation of the unit. Respect the following advices to minimize the risk in injury or even serious 

injury or danger for life. 
 

 

 

Attention 

The installation of the unit has to be done in accordance with the local safety norms (e.g. for Germany DIN/ VDE) 

and all other relevant governmental norms and laws. 

During the operation all covers of the unit have to be closed. Disconnect unit components from power supply prior 

to maintenance or repair work and secure against reconnection. 

 

 

Danger 

Please note the information in these operating and installation instructions about dangers, warnings and 

precautions. 

 

General 

Obey all safety notes and warnings present on the unit. 

In case of a malfunction, switch off the unit immediately and prevent a restart. Repair malfunctions immediately. 

After any repair work, have qualified personnel check the safe operation of the unit. Use original spare parts only. 

Additional national safety regulations also fully apply to the operation of this unit. 

Always use original spare parts! 

 

 

Accident Prevention Regulations 

Comply with the accident prevention regulation 
Accident Prevention Regulation Electrical Systems and Equipment (VBG4/BGVA2) must be observed to prevent 

injury to yourself and others. 

 

 

Operation of the Unit 

Do not perform any work which compromises the safety of the unit. 

Regularly check that all safety and monitoring devices are functioning normally. 

Do not remove or disable safety devices. 

 

 

Installation, Disassembly, Maintenance and Repair of the Unit 

Attention:  

Work on the electrical system may only be performed by suitably trained personnel. 

Disconnect unit components from power supply prior to maintenance or repair work. 
Attaching or installing 

additional components 

is permitted only with the 

consent 

of the manufacturer.  

In case of faults in the power supply switch off the device immediately. 
Use only original fuses with the appropriate amperage rating. 

 

 

Disposal after De-installation 

Note:  

The operator is responsible for the disposal of unit components as required by law. 
 

 

Summary of Contents for Duftdos UNPL

Page 1: ...bols 2 2 Saftey 3 2 1 Technical safety advice 3 2 2 Use in accordance with regulations 4 3 Delivery 4 4 Function 4 5 Technical Data 5 6 Fragrance pump 5 6 1 Change the hose set 6 6 2 Sparepartlist per...

Page 2: ...essible at all times 1 4 Further informations For further information please contact your dealer or company WDT Werner Dosiertechnik GmbH Co KG 1 5 Used symbols Danger Warning of Danger Failure to obs...

Page 3: ...y After any repair work have qualified personnel check the safe operation of the unit Use original spare parts only Additional national safety regulations also fully apply to the operation of this uni...

Page 4: ...After you press the push button the dosing is activated for 0 5 seconds till 5 seconds adjustable and aroma is injected into the steam pipe Afterwards the dosing is locked for an adjustable 1 20 minu...

Page 5: ...6 Fragrance pump A peristaltic dosing pump is used for dosing which safely promotes also smallest quantities Even when Air or gas bubbles are trapped in the suction line Rotating rolls press the dosi...

Page 6: ...t persitaltic pump frangrance The peristaltic pump article no Transparent pump cover Sa 14259 Safety disc for roller Sa blue 13633 Hose holder Sa for fragrance with Viton hose 13358 Hose set Sa 2 dosi...

Page 7: ...ommissioning Dosing The dosing unit has to be mounted in an easily accessible place on the wall about 1m above the floor The fragrance canister is placed under the unit The suction hose is inserted in...

Page 8: ...sensor head Then you adjust the desired dosing value at the rotary knob for the dosage The dosing pump delivers per second running time approximately 1 ml fragrance The green LED indicates the unit i...

Page 9: ...suring points is 730 ohms If the switch on temperature should be changed so you can do these when you turn the adjustment screw at the potentiometer If you turn clockwise the switch on temperature wil...