www.Wayne-Dalton.com
349981 REV2_05/17/2016
©
Copyright 2016 Wayne Dalton, a division of Overhead Door Corporation
40
Fig 6–C
INPUT SIGNAL
ACTIVATION DESCRIPTION`
Manual
Momentary activation opens door unless the door is already at an open position. In this case, the door will close.
1) If the Manual timer is set to a value greater than zero, the controller delays closing of the door until the timer expires.
Open
Opens the door to fully open position when activated.
Auto 1
Momentary activation opens door to the fully open position limit. Upon deactivation the controller delays the door for the
duration of the Auto timer. If reacivated during this time delay, the timer will be reset and will begin to decrement when
the input is again deactivated. Upon expiration of the timer, the controller closes the door to fully closed position. If timer
is not used, the door will stay in the open position when activated.
Stop
Momentary activation stops the motion of the door.This input uses the Stop Deceleration Ramp set under the System
Config menu.
This input is also used to clear certain error conditions.
Close
Closes the door to fully open position when activated
Emergency Stop
Activation immediately halts the door in motion.
This input uses the Emergency Deceleration Ramp set under the
System Config menu.
Safety Edge
Activation during a closing cycle stops the door and then reverses the door motion back to the fully open position limit.
An “E10 Safety Edge Activated” error occurs.
Photoeye
Activation during a closing cycle stops the door and then reverses the door motion back to the fully open position limit.
Lock Open
Activation causes the controller to hold the door at the fully open position limit. The input must be continously activated
to maintain the locked open state. Deactivating this input unlocks the door and allows normal operation.
Lock Close
Activation causes the controller to hold the door at the fully closed position limit. The input must be continously activated
to maintain the locked open state. Deactivating this input unlocks the door and allows normal operation.
Open Jog
Activation of this input moves the door in the direction of the fully open limit at Jog speed. Deactivating this input stops
the door in motion. Activation during closing does not open or stop the door.
Close Jog
Activation of this input moves the door in the direction of the fully closed limit at Jog speed. Deactivating this input stops
the door in motion. Activation during opening does not close or stop the door.
Breakaway
Activation halts door motion.
Open Position 1
Activation opens the door to the partial open 1 position limit. If activated during closing, door will reverse to 1 position
limit.
Open Position 2
Activation opens the door to the partial open 2 position limit. If activated during closing, door will reverse to 2 position
limit.
Open Part 1 Auto
Activation opens the door to partial open 1 position limit. The controller then delays the door for the duration of the Auto
Timer. Upon expiration of the timer, the door closes fully.
Open Part 2 Auto
Activation opens the door to partial open 2 position limit. The controller then delays the door for the duration of the Auto
Timer. Upon expiration of the timer, the door closes fully.
Flip Flop
Activation reverses the door operation. If door is closed, activation opens the door and vise versa. When door is closing
and activated, the door reverses and begins opening and vise versa.
Man Part 1
Activation opens the door to the partial open 1 position limit, if not already at this position. If the door is already at this
position, the door closes.
Man Part 2
Activation opens the door to the partial open 2 position limit, if not already at this position. If the door is already at this
position, the door closes.