96
•
SmartSensor HD User Guide
Setting
Description
Details
All three pushed data types
HD
Native SmartSensor
HD (SS125) format.
Use this for a
standard SmartSensor
HD system.
SS105 Simple
Emulates the original
SmartSensor (SS105)
format, without a
multi-drop header.
Use this when
you’re using the
SmartSensor HD
in a system that
was designed for a
SmartSensor 105.
SS105 Multidrop
Emulates the original
SmartSensor (SS105)
format, with a multi-
drop header.
Use this when
you’re using the
SmartSensor HD
in a system that
was designed for a
SmartSensor 105.
Event data only
Z4 2-Loop
Emulates a dual-
loop system. Speed
and duration are
measured using the
loop size and spacing
set in the Loop
Emulation settings.
Use this when
you’re using the
SmartSensor HD in
a system that was
designed for dual
inductive loops.
Z4 1-Loop
Emulates a single-
loop system. Duration
is measured using
the loop size set in
the Loop Emulation
settings.
Use this when
you’re using the
SmartSensor HD in
a system that was
designed for single
inductive loops.
Z4 2-Loop Pulsed
Emulates a dual
loop system; outputs
will be held active
for 125 ms for each
vehicle detected, so
only speed will be
measured.
Use this when
you’re using the
SmartSensor HD in
a system that was
designed for dual
inductive loops and
all you need is vehicle
presence and speed.
Definition.
Z4 is a
Wavetronix-specific
protocol that lets
sensors talk to other
Wavetronix devices,
mostly contact
closure devices.
Note.
The Loop
Emulation settings
are found on the
Settings screen and
covered in chapter 5.
Summary of Contents for SmartSensor HD