First steps 

 

 

page 20 of 30 

 

Opening the software editor 

Make sure that your WaveU is already connected to your computer. Now 
open the WaveU software editor. You have also downloaded it from our 
site before. You should now see the main window: 

 

You can see if your WaveU is connected to the software in the lower left 

corner of the device overview. The con-
nected WaveU and its serial number are 
displayed here. 

You can also connect multiple WaveUs. In 
this case, you can use the drop-down field 
to select the WaveU you want to use. 

Loading a card 

Click the Open Card button. A dialog box opens. Here you can select a 
previously saved card. The files have the extension *.wru. 

If your files are in another folder, navigate to the desired folder via the win-
dow. 

Double-click on the file or select it and click the Open button. The contents 
of the card will be loaded and displayed in the main window. 

 

Summary of Contents for WaveU

Page 1: ......

Page 2: ...don t want to expose yourself and your environment to unnecessary dan ger do you Your WaveReX Team This is a product to praise the glory of Roland and its outstanding musical products Note We assume n...

Page 3: ...Manual Revision English Version 1 0 19 12 2022 Many Thanks to Emily Anne Rainer Buchty Tobias Hopp Dirk Stephan and all our sup porters How to reach us www waverex de www waverex com www shop waverex...

Page 4: ...0 The USB port 10 The card 10 THE SOFTWARE EDITOR 11 The user interface 11 New Card Button 11 Open Card button 11 Save Card button 11 Save Card As button 11 General area 12 Play button 12 Card Info 12...

Page 5: ...ing a loop 24 Loop Modes 25 Special feature of the loop 26 File formats 27 Saving a card 27 Transferring a card 28 And go to the U 29 TECHNICAL DATA 29 TROUBLESHOOTING 30 My card is not recognized in...

Page 6: ...s state of the art electronic com ponents and was developed and built according to the current state of the art ATTENTION Use WaveU only in rooms with room temperature and low humidity Do not expose W...

Page 7: ...s any obvious damage If you are not sure con tact support A defective device can severely damage your WaveU ATTENTION Do not use WaveU if your device has a defect Faulty voltages short cir cuits etc c...

Page 8: ...ndheitsanforder ungen der nachstehend aufgef hrten EU Richtlinien entspricht Bei einer mit uns nicht abgestimmten nderung des Produktes verliert diese Erkl rung ihre G ltigkeit Die alleinige Verantwor...

Page 9: ...n the Roland D 70 at your own risk Preparation To connect WaveU to your computer you need a micro USB cable This is not included in the delivery You can also use a USB extension but make sure that the...

Page 10: ...a little tight Never insert your USB cable with force you can destroy the connector The card The card was manufactured in a sandwich process from conventional board material GRP The layers are both so...

Page 11: ...U as card sounds 128 tones are possible per card The user interface New Card Button Press this button if you want to discard your composition and create a new one Open Card button With this button yo...

Page 12: ...and Voice 2 for tones with two voices Play button Press Play to preview the currently selected sample Alterna tively you can press the space bar Card Info Here you will always see information about th...

Page 13: ...the bottom in forms you about the progress of the transfer Knobs You can operate each knob in several ways You can click on it with the left mouse button and move the mouse up or down The knob moves...

Page 14: ...be distributed over several keyboard zones Use the Plus button to add a new empty sample to your list Then double click the sample to assign a file to it Alternatively you can add files to the list by...

Page 15: ...p Activate the checkbox lock Loop to keep the loop length when the loop start or sample end is changed Pitch settings The drop down field allow you to set the root note for the currently se lected sam...

Page 16: ...ime and L1 to the attack level The course of this part of the envelope is always linear T2 is the time until the level has changed from L1 to L2 L2 can be higher or lower than L1 If both levels are th...

Page 17: ...over the slider the currently set dB value is displayed via a tooltip If you want to know exactly and do all the math calculate 20 log10 x 1 127 X stands for the integer value set at the controller Th...

Page 18: ...ort WaveU will be powered when the green LED is lit Your WaveU will start in bootloader mode for five seconds You can see this by the double blinking of the blue LED After that your WaveU will au toma...

Page 19: ...ter Then specify the folder of the USB driver under Search for driver software in this loca tion Confirm with Next Windows will then install the driver for WaveU WaveU will be displayed in the Device...

Page 20: ...The con nected WaveU and its serial number are displayed here You can also connect multiple WaveUs In this case you can use the drop down field to select the WaveU you want to use Loading a card Clic...

Page 21: ...he list A new initially empty Tone is created Each tone consists of at least one voice at most two voices which correspond to a multisample Samples can be assigned to these voices later Rename a tone...

Page 22: ...name as displayed in your U defaults to WaveU However you can change it at any time to your liking The Card Name text box is located in the upper left corner of the main window Creating a tone Click...

Page 23: ...is set to 64 and it is a Velocity Switch type Tone Voice 1 will play for all velocities up to 64 and Voice 2 will play for all velocities above 64 Tone Types Single this is a Tone that consists exclu...

Page 24: ...e sample you want to add to your voice Double click on your selection or confirm by clicking OK The second way to add a sample is by drag and drop Simply drag your sample over the samples list and rel...

Page 25: ...wave for example If the sample ends for example with the zero crossing of the negative oscillation the loop must start with the positive half wave Otherwise this happens If the Loop Mode Alternating A...

Page 26: ...sible This is indicated by the coloring of the loop offset If the address is red you can be sure that the loop will not work or the de vice does not read this address as it is written on the card Howe...

Page 27: ...those interested please note that the U s samples must be provided in a format compressed to 7Bit So a higher bit depth than 16Bit does not help at all to a higher quality Please note Currently only W...

Page 28: ...card are always occupied by the card format Click on Send Card in the lower right corner to start the transfer The left corner of the WaveU flashes blue to indicate that the transfer is in progress Y...

Page 29: ...sis Now switch on your U When the card is correctly inserted the upper right corner of your WaveU will light up green indicating that your WaveU is powered by the device Now select a patch on the devi...

Page 30: ...e contact support at support waverex de The software editor does not show my WaveU Please make sure that your WaveU is installed correctly Please refer to the section Installing the USB driver If this...