PLDXK-CH SERIES LASER DIODE DRIVER
ELECTRICAL SPECIFICATIONS
PARAMETER
SYMBOL
VALUE
UNIT
NOTE
ABSOLUTE MAXIMUM RATINGS
Supply Voltage (H1:2)
+5 V
5.0 to 5.5
VDC
See Power Supply Requirements on
Supply Voltage, (H1:3)
1
PLD12.5K-CH laser supply
High Compliance laser
LD Anode
4.5 to 30
VDC
Consult Safe Operating Area calculator for supply
voltages > 5 VDC, see
requires two power supplies, see
Supply Voltage, Type C Lasers
1
Aux V+
8.0 to 12.5
VDC
Operating Temperature Range
2
T
OPR
0 to 50
ºC
Storage Temperature Range
T
STG
-55 to 125
ºC
Weight
3.2
oz
89.6 g
Size
1.12 x 2.35 x 3.2
in
28.5 mm x 59.7 mm x 81.3 mm
1. For two-supply operation, it is critical to shut down the power supply to the laser first before shutting down the +5V supply powering the electronics.
2. Maximum operating temperature of PLD12.5K-CH is 35ºC.
MODEL
PARAMETER
PLD5K-CH
PLD10K-CH
PLD12.5K-CH
UNIT
NOTE
DRIVE CURRENT OUTPUT
Max Internal power Dissipation
40
W
Max Output Current
5
1
10
1
12.5
1
A
Compliance Voltage
2
3 V max with 5 V power supply input
28 V max with 30 V power supply input
85 V max with Product Variation
V
Short Term Stability, 1 hour
< 100
< 200
< 200
ppm
Quiescent Current
150
150
250
mA
Temperature Coefficient
< 200
ppm / ºC
Noise & Ripple
3
> 45
µA
PHOTODIODE FEEDBACK
High Range, Type A & B Lasers Only
50 - 5000
µA
Low Range
15 - 500
µA
Constant Power Mode
Output Stability
< 0.02
< 0.05
< 0.05
%
EXTERNAL MODULATION
Analog Input Damage Threshold
–0.5 V < ANALOG IN, or
ANALOG IN > (Supply V 0.5V)
V
Input Pin Impedance
1
MΩ
3 dB Bandwidth, Constant Current
4
120
80
50
kHz
BW at 90% Depth of Modulation
4
70
70
40
kHz
Constant Current Mode
Output Rise / Fall Time
4.8 / 9.4
5.9 / 10
8 / 9
µsec
TIMING CHARACTERISTICS
Output Turn-On Delay
≥1.5
seconds
Slowstart Output On-Time
250
msec
Disable Fall Time
>100
µsec
MONITOR ACCURACY
Monitor Voltage vs. Expected Output
based on transfer function
2
% of Full
Scale
1.
To achieve maximum rated current, the power supply voltage may need to be 5.5 VDC because the impedance of external wiring may reduce
the voltage at the laser driver.
2. Compliance voltage depends on power supply voltage. In high-compliance
mode, a maximum compliance voltage of 28 V is obtained using a 30 VDC
power supply. A 5 VDC power supply input results in 3 V compliance voltage.
3. Not recommend for low noise applications. See the
for lower noise laser drivers
4.
Peak-to-peak output amplitude decreases as frequency increases; see figure at right.
Note: 90% DOM for PLD12.5K-CH is at 40 kHz.
0 mA
Full Current
100% Depth of Modulation at 10 Hz
100 %
0 %
90% Depth of Modulation at 70 kHz
90 %
95 %
5 %