background image

User Manual

W51PC DCOM Interface 

V1.1

By WAVECOM ELEKTRONIK AG

Summary of Contents for W51PC

Page 1: ...User Manual W51PC DCOM Interface V1 1 By WAVECOM ELEKTRONIK AG...

Page 2: ...in whole or in part in any form is prohibited without written consent of the copyright owner The publication of information in this document does not imply freedom from patent or other protective righ...

Page 3: ...te Control Interface 4 Class W51Server 4 Iw51System 4 Iw51System Methods 5 Iw51DataSink 8 Iw51DataSink Methods 9 RawData format for FAX 10 Class W51Param 10 ICW51Param 10 ICW51Param Methods 10 List of...

Page 4: ......

Page 5: ...sional versions are only available to government bodies WAVECOM maintains a mailing list of our professional customers For registration details see Appendix at the end of this manual Options Different...

Page 6: ...g projects Manufacturing is outsourced to specialized companies within Switzerland which can handle today s needs for processing surface mount components and fine pitch structures WAVECOM ELEKTRONIK A...

Page 7: ...s The first is a compre hensive interface providing all the functionality required by the WAVECOM Client application The second interface is a simplified inter face providing only the functions requir...

Page 8: ...User locate and start decoding a signal 2 Card communicate parameters to server 3 Client Application retrieve parameters from server using the Iwxx System interface 4 Client Application save paramete...

Page 9: ...d Iw51System Methods Shown below is the IDL definition of the Iw51System interface Each of the functions or methods will be described interface IW51System IDispatch HRESULT Connect in BSTR CardName HR...

Page 10: ...he Server can be started by running the Server Control application To show you all the possible combination up to 3 computers are needed Remote Client WAVECOM SERVER W51PC Card Command PC 1 PC 1 PC 1...

Page 11: ...w data as a bit stream from the card The cMax para meter indicates the maximum length of the buffer used to receive the da ta The pcActual parameter indicates the actual length of the data re ceived D...

Page 12: ...synchronization in the current mode Iw51DataSink The client application can use the Iw51DataSink interface to receive the decoded data from the decoder Card The decoded data can be text bitmap or sign...

Page 13: ...sing in long Level Three distinct types of data can be returned from the Server These are text data raw data for example fax bitmap etc and system status re sults The rate at which the server calls th...

Page 14: ...0 rpm 480 pixel line HELL 28 pixel line Color Table for FAX modes In the FAX modes PRESS FAX WEATHER FAX METEOSAT NOAA GEOSAT the values from 0 to 255 represent specific colors which are used for draw...

Page 15: ...Name is the parameter name and Value is a BSTR containing the value of the parameter The Name and Value strings are case sensitive HRESULT GetParam in BSTR Name out BSTR Value This function retrieves...

Page 16: ...ANGLE HAMMING HANNING BLACKMAN Filter response SLOW NORMAL FAST Frame length 3 4 5 6 7 8 9 22 Frame format 2400 SHORT 1200 SHORT 600 SHORT 300 SHORT 150 SHORT 75 SHORT 2400 LONG 1200 LONG 600 LONG 300...

Page 17: ...l rate 25 0 2400 0 PSK Sync mode SYNC ASYNC PSK Zoom 500 1000 4000 12000 24000 Repetition cycle 4 5 8 Scan mode FAST FULL Shift AF IN IF IN VAR 50 3500 IF IN 10 7 IF IN 21 4 50 16000 Sreg 72 128 OFF T...

Page 18: ...ARQ M4 242 ARQ M4 342 ARQ N ASCII ATIS AUM 13 AUTOSPEC BAUDOT BULGASCII CCIR 1 CCIR 7 CCITT CIS 11 CIS 14 CIS 36 CIS 36 50 CIS 50 50 CODAN COQUELET 13 COQUELET 8 COQUELET 80 CTCSS CW MORSE DCS SELCAL...

Page 19: ...NAGRAM HF FSK ANALYSIS HF FSK CODE CHECK HF MFSK ANALYSIS HF OSCILLOSCOPE HF PSK PHASE PLANE HF PSK SYMBOL RATE HF REAL TIME FFT HF SONAGRAM HF WATERFALL HNG FEC ICAO SELCAL METEOSAT MFSK 16 MFSK 20 M...

Page 20: ...O SI FEC SITOR ARQ SITOR AUTO SITOR FEC SP 14 SPREAD 11 SPREAD 21 SPREAD 51 SSTV STANAG 4285 STANAG 4415 STANAG 4481 PSK STANAG 4529 SWED ARQ TWINPLEX VDEW VHF AUTOCORRELATION DIR VHF AUTOCORRELATION...

Page 21: ...VHF WATERFALL DIR VHF WATERFALL IND VISEL WEATHER FAX ZVEI 1 ZVEI 2 ZVEI VDEW These W51 modes and analysis tools may only be activated i e data CANNOT be retrieved through the remote control interface...

Page 22: ...ram CREATEOBJECTEX clsidparam oDecSys connect W51CardA oDecSystm GetParam lcBlop oDecParam SetBlob lcBlop oDecParam SetParam Mode mode oDecParam GetBlob lcBlop oDecSystm SetParam lcBlop oDecSys Activa...

Page 23: ...stantiation of it Err 0 Set m_objW51Server1 CreateObject W51System W51System 1 Connect to the card m_objW51Server1 Connect Format One Set the interface parameters m_objW51Server1 SetParam m_objW51Serv...

Page 24: ...c analysis in MATLAB Tested with Matlab 6 5 Release 13 Instantiate w51PC w51 actxserver W51System W51System 1 w51 ConnectByNumber 0 blob invoke w51 GetParam text invoke w51 GetTextData change decoder...

Page 25: ...mes re ferred to as 3 to 4 encoding Each 6 bits of the 24 bit group is used as an index into a mapping table the base64 alphabet to obtain a character for the encoded data base64 mime Scheme used to t...

Page 26: ...ed and failed to head this off by adding an extra http transport to DCE RPC called DTD Can accompany a document essentially defining the rules of the docu ment such as which elements are present and t...

Page 27: ...characters in the Unicode range U 0000 to U 007F Well formed A textual object is a well formed XML document if Taken as a whole it matches the production labeled document It meets all the well formed...

Page 28: ......

Page 29: ...Sink 8 Iw51DataSink Methods 9 Iw51System 4 Iw51System Methods 5 L List of Parameters 11 List of parameters supported by W51System class 11 M MATLAB 20 Microsoft C 20 O Options 1 P Professional Version...

Reviews: