CARDIO WAVE EXCITE Class & Trend: Service & maintenance manual- rev.2.0
Pagina 6.6
MAN.KEYBOARD
TEST
TROUBLESHOOTING
I2C Devices Test
AUTOMATIC TEST
MANUAL TEST
LED Test
SERIAL PORTS
TEST
CSafe COM Test
TGS COM Test
Low Kit COM Test
To scroll through the list of available functions, press the
+
or – effort level keys to display the next
or the preceding item; confirm the choice by pressing
ENTER
. To cancel the operation, press the
CLEAR
key for a few seconds.
The tests are divided into two groups: Automatic and Manual, and the prompt for a choice appears
immediately on accessing the troubleshooting menu.
6.2.1.
A
UTOMATIC
T
EST
The tests grouped under this section conduct checks on the machine’s operation in a fully automatic
manner. After selecting the desired test using the
+
and – effort level keys, press
ENTER
to initiate
the test and then await the result. Press
ENTER
again to continue, and use the
CLEAR
key to
return to the higher menu level, holding it down for a few seconds. The various tests are described
below.
6.2.1.1.
I2C Devices Test
The I2C Devices test checks the communication following the 32K and 256K. The test can have
outcomes:
•
“Test Successful, press Enter to continue”: Signifies that the transmission and reception of
data packets between the I2C devices and the display board was completed successfully.
•
“EEPROM Error, press Enter to continue”: Signifies that the display board is having
problems communicating with its memories.