wattstopper EW-200-120 Installation Instructions Manual Download Page 1

SPECIFICATIONS

Voltage:

 

EW-200-120, EW-205-120 ............................................. 120VAC, 60Hz

 

EW-200-277, EW-205-277 ............................................. 277VAC, 60Hz

Mountable Locations  ......................................Wall, ceiling or under eaves

Operating Temperature...................................-40° to 130°F (-40° to 55°C)

Lens Coverage: .................................................................................... 270°

Load Ratings ................................. 0–1000W ballast or tungsten @120VAC

 

 ...................................................................0–1000W ballast @277VAC  

Motor Load:  ........................................................................1/6 HP @20VAC

 

 ...................................................................................1/3 HP @277VAC

Current Consumption

 

Without Isolated Relay.......................................................22 mA max.

 

With Isolated Relay  ...........................................................34 mA max.

Time Delay Adjustment . . . . . .............................................. 12sec.–16min.

Light Level Adjustment .......................................................... 0.5FC–200FC

Isolated Relay on EW-200 (both -120 & -277 models)

 

Normally Open & Normally Closed contacts.

Isolated Relay Rating: .........................................................1A @ 30VAC/DC

UL 773A Raintight Rated

IEC-IP-55 Rated

Ins
tallation Ins

tructions

U.S.Patents: 4,787,722; 5,640,113

EW-200 & EW-205

 Outdoor  PIR Motion Sensors

Santa Clara, CA 95050

800.879.8585

Model#s: 

EW-200-120  

EW-200-277

EW-205-120  

EW-205-277

Summary of Contents for EW-200-120

Page 1: ...P 277VAC Current Consumption Without Isolated Relay 22 mA max With Isolated Relay 34 mA max Time Delay Adjustment 12sec 16min Light Level Adjustment 0 5FC 200FC Isolated Relay on EW 200 both 120 277 models Normally Open Normally Closed contacts Isolated Relay Rating 1A 30VAC DC UL 773A Raintight Rated IEC IP 55 Rated Installation Instructions U S Patents 4 787 722 5 640 113 EW 200 EW 205 Outdoor P...

Page 2: ...D INSTALLATION 5 DIAL ADJUSTMENTS 7 Adjust Time Delay 7 Adjust Light Level 7 Making Changes 8 SECURITY OVERRIDE 9 TROUBLESHOOTING 9 ORDERING INFORMATION 10 WARRANTY INFORMATION 10 CAUTION READ ALL OF THE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THIS PRODUCT THIS UNIT USES HIGH VOLTAGE IT SHOULD ONLY BE INSTALLED BY QUALIFIED PERSONS THAT ARE THOROUGHLY FAMILIAR WITH PROPER SAFETY PROCEDURES AND...

Page 3: ...5 270 coverage Coverage adjustment The front of the sensor housing can be moved up and down for easy coverage adjustment Call 1 800 879 8585 or 1 972 578 1699 For Technical Support 2 COVERAGE PATTERN Coverage is shown as tested in a controlled setting with the unit mounted at 8ft at a 10 tilt from the horizontal surface The actual outside coverage pattern may vary substantially at the specific ins...

Page 4: ...er plate mounting as shown in the illustration on the right Horizontally mounted For horizontal mounting such as under eaves rotate the sensor housing as shown in the diagrams below Make sure that the gasket is seated properly Loosen the two screws at the back of the sensor Rotate the sensor housing 180 Replace and tighten the screws Check Our Web Site For FAQs www wattstopper com 3 1 2 3 Attach m...

Page 5: ...able vibration free surface Avoid runoff sheltered locations preferred Aim motion sensor downward to limit sensing Mount motion sensor level Do not mount by vents or above lamps Mount sensor below lamps to avoid heat effects YES YES YES YES NO NO NO NO NO NO NO Call 1 800 879 8585 or 1 972 578 1699 For Technical Support YES ...

Page 6: ...r sensor also see instructions page 6 Attach cover plate assembly and gasket to the junction box with 4 screws and screw covers supplied IMPORTANT Make sure that the gasket seats properly when attaching the cover plate Attach cover plate assembly and gasket to the junction box with 4 screws and screw covers supplied IMPORTANT Make sure that the gasket seats properly when attaching the cover plate ...

Page 7: ...ications front cover Isolated Relay EW 200 models only See Specifications front cover for rating Connect the wires necessary to the application that requires this output ORANGE Common must be used for proper operation GREEN Normally Closed Open when occupancy is detected YELLOW Normally Open Closed when occupancy is detected Call 1 800 879 8585 or 1 972 578 1699 For Technical Support 6 Note Note W...

Page 8: ...or inactive Wait until daylight levels have reduced before testing again 5 See Dial Adjustments below for guidelines to adjust the time delay and light level to the desired settings for operation DIAL ADJUSTMENTS Time Delay and Light Level control dials are located on the bottom of the sensor 1 Adjust Time Delay The time delay is the amount of time that elapses before lights turn off since the sen...

Page 9: ...oon icon as desired this lowers the light level setting Remember the sensor must detect motion for lights to turn on The lights turn on later in the evening The lights turn off sooner in the morning Notes When testing adjustments make sure not to block any of the light that is reaching the sensor or reflect any light into the sensor s lens The sensor requires about 5 seconds for light level adjust...

Page 10: ...ere is no movement in the coverage area the sensor should turn lights off low in 12 seconds Reset the time delay to the desired value 3 If the lights do not turn off low have a person qualified to check high voltage connections verify that the sensor and lighting are wired correctly see Wiring and Installation page 5 6 CAUTION Make sure power is turned off at the circuit breaker before checking wi...

Page 11: ...120VAC 60Hz 270 Outdoor Indoor PIR Motion Sensor includes cover plate EWF 205 120 120VAC 60Hz 270 Outdoor PIR Motion Sensor includes two lamp holders and cover plate EW 200 277 277VAC 60Hz 270 Outdoor Indoor PIR Motion Sensor with Isolated Relay includes cover plate EW 205 277 277VAC 60Hz 270 Outdoor Indoor PIR Motion Sensor includes cover plate When ordering add W for Arctic White or G for Archit...

Page 12: ...2800 De La Cruz Boulevard Santa Clara CA 95050 USA Technical Support 800 879 8585 www wattstopper com 00335r4 09 2014 Please Recycle ...

Reviews: