BZ-200, BZ-250, BZ-250-347
Power Pack
Ins
tallation Ins
tructions
SPECIFICATIONS
Voltages
BZ-200, BZ-250 ..................... 120—277 VAC, 50/60 Hz, single phase
BZ-250-347 ............................ 120—347 VAC, 50/60 Hz, single phase
Load Requirements
Ballast/ELV/MLV/Incandescent/LED
BZ-200, BZ-250 ............................................ 20 A @ 120—277 VAC
BZ-250-347 ................................................... 16 A @ 120—347 VAC
E-Ballast/CFL ................................................... 16 A @ 120—277 VAC
Motor
BZ-200, BZ-250 ..............................................1 HP @ 120/240 VAC
BZ-250-347 ................................................ 1/4 HP @120—347 VAC
Plug Load
(BZ-200, BZ-250) ....................................................20 A @ 120 VAC
(BZ-250-347) ...........................................................15 A @ 120 VAC
Class 2 Output
BZ-200 (w/relay connected) ...................................225 mA @ 24 VDC
BZ-250, BZ-250-347 ...............................................225 mA @ 24 VDC
Low Voltage Input, Control ON ............................................... 5—30 VDC
Operating Temperature ................................... -4°—131 °F (-20—55 °C)
Storage Temperature ..................................... -40°—176 °F (-40—80 °C)
UL/C-UL Listed
Auto/Manual
Mode Switch
BZ-250,