Installation – 2" Pipe
T
h
e
f
lo
w
t
hru
t
h
e
Sc
ale
N
et
®
C
o
mm
e
rc
ial
W
ate
r
T
r
eat
m
ent
S
yste
m
is
upw
a
rd.
T
h
e
r
e
f
o
r
e
,
t
h
e
inlet
c
onne
c
tion
is
at
t
h
e
b
otto
m
o
f
t
h
e
tan
k
an
d
o
u
tlet
c
onne
c
tion
is
at
t
h
e
to
p.
T
h
e
f
lo
w r
ate
mu
st
not
e
xc
ee
d
t
h
e
m
a
x
i
mum
s
p
e
c
i
f
ie
d f
lo
w r
ate
o
f
t
h
e
syste
m. A f
lo
w c
ont
r
ol
d
e
v
ise
w
ill
b
e
r
e
qu
i
r
e
d f
o
r
a
pp
li
c
ations
wh
e
r
e
f
lo
w r
ates
m
ay
e
xc
ee
d
t
h
e
m
a
x
i
mum
s
p
e
c
i
f
ie
d f
lo
w r
ate
.
I
nstallation
I
nst
ruc
tions
:
1.
P
la
c
e
syste
m
on
a
s
m
oot
h f
lat
s
urf
a
c
e
.
2.
I
t
is
r
e
c
o
mm
en
d
e
d
t
h
at
t
h
e
syste
m
is
installe
d w
it
h
a
f
iel
d c
onst
ruc
te
d 3 v
al
v
e
b
y
p
ass
.
3.
C
onne
c
t
in
c
o
m
in
g c
ol
d w
ate
r
to
t
h
e
inlet
o
f
t
h
e
syste
m.
4.
C
onne
c
t
syste
m
o
u
tlet
to
t
h
e
se
rv
i
c
e
w
ate
r
line
in
t
h
e
bu
il
d
in
g.
5.
P
a
r
tially
o
p
en
a
v
al
v
e
d
o
w
n
st
r
ea
m
o
f
t
h
e
syste
m
to
allo
w
t
h
e
ai
r
to
purg
e
fr
o
m
t
h
e
syste
m.
6.
S
lo
w
ly
o
p
en
inlet
v
al
v
e
an
d
allo
w
t
h
e
syste
m
to
f
ill
w
it
h w
ate
r.
7.
C
lose
t
h
e
d
o
w
n
st
r
ea
m v
al
v
e
f
i
v
e
m
in
u
tes
a
f
te
r
all
t
h
e
ai
r h
as
b
een
purg
e
d
fr
o
m
t
h
e
syste
m
an
d p
l
umb
in
g.
T
h
is
f
l
u
s
h
es
any
f
ines
o
u
t
o
f
t
h
e
syste
m.
8.
Ch
e
ck f
o
r
lea
k
s
an
d r
e
p
ai
r
as
r
e
qu
i
r
e
d.
9.
S
yste
m
is
r
ea
d
y
f
o
r u
se
.
C
on
d
itions
f
o
r Op
e
r
ation
:
•
M
ini
mum pr
ess
ur
e
15 PSI
•
M
a
x
i
mum pr
ess
ur
e
125 PSI
•
M
ini
mum
o
p
e
r
atin
g
te
mp
e
r
at
ur
e
34 F
•
M
a
x
i
mum
o
p
e
r
atin
g
te
mp
e
r
at
ur
e
120 F
•
W
ate
r pH r
an
g
e
6.0
to
9.0
•
M
a
x
i
mum f
ee
d w
ate
r h
a
rd
ness
is
75 gr
ains
p
e
r g
allon
.
•
H
y
dr
o
g
en
s
u
l
f
i
d
e
,
i
r
on
,
an
d m
an
g
anese
pr
et
r
eat
m
ent
r
e
qu
i
r
e
d
•
M
a
x
i
mum ch
lo
r
ine
3 ppm, d
e
-ch
lo
r
ination
r
e
c
o
mm
en
d
e
d
•
O
il
an
d gr
ease
s
h
o
u
l
d
not
b
e
pr
esent
Warning - Do not exceed specified flow rates
Part Number Tank Size Pipe Size Max Service Flow
M8414-COM 14x65
2"
50
gpm
M8416-COM 16x65
2"
75
gpm
Inlet
O
utlet
Note: Do not use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit.
System must be maintained according to manufacturer's instructions. Pre-treatment for sediment, Iron, Hydrogen Sulfide, Manganese, hydrocarbons
and copper may be required depending on conditions. Install systems in new homes with copper pipe after six weeks of water use.