Lync WQ-SF
SECTION 3: Operation
L- OMM-004_A
•
2/23/2022
Technical Support • (800) 433-5654 • Mon-Fri, 8 am - 5 pm EST
28
of
54
18. Allow water to flow from the hot and cold side treated faucet until all air has been purged from
the plumbing system. Then close both the hot and cold side treated water faucet.
19. Turn on water heaters.
3.6.
User Mode Programming Flow Chart
•
Press and hold the
Down
and
Up
buttons simultaneously for 3 seconds to enter User
Programming mode.
•
To navigate, press the
Extra Cycle
button to advance to the next value. Press the
Left
button to retreat to the previous value.
•
Where applicable, use the
Up
and
Down
buttons to adjust a value as desired.
•
After progressing through all available values, the controller will return to Normal
operation.
•
To exit diagnostic mode, progress through all available values, press and hold the
Left
button at any time, or after 5 minutes of inactivity the controller will return to normal
operation automatically.
•
Depending on the current controller programming, certain values may not be able to be
viewed or set.
•
The controller will display local information, not system information.
•
In the event of a regeneration occurring while displaying user programming, the
regeneration step and time remaining will be displayed. When regeneration has been
completed, the display will return to the main screen.
Example:
Range: Off - 99 Days
Example:
Range: 0 - 23 Hours 59 Minutes
Example:
Range: 1 - 999 grains per gallon
Example:
Range: 1 - 99999 gallons
3.7.
Time of Day Programming Mode Flow Chart
NOTE:
Set Time of Day on any unit and the rest of the units in the system will update the Time of
Day automatically.
•
Press and hold the
Up
button for 2 seconds. The “Time” value is displayed. Press the
Up
or
Down
buttons to adjust as desired.
•
Press the
Extra Cycle
button to advance to the “Year” field. Press the
Up
or
Down
buttons to adjust as desired.