background image

IS-150A

Installation Instructions
Series LF150A/LF150-HA

Water Hammer Arrestor for Residential Applications

Installation Instructions

•  Install as close as possible to source of shock.

•  Avoid damaging arrestor by using hex flats to tighten.

•  Unit is factory pre-charged to 30psi (207 kPa). If system pressure is  

higher than 35psi (241 kPa), add air until the valve is 5psi (34 kPa) 

below the system flow pressure.

•  Use LF150HA hose adapter for hose applications such as direct  

mounting to Watts Model 2, Duo-Cloz washing machine shutoff valve.

•  Maximum working pressure 150psi (10.3 kPa).

LF150A

LF150A

LF150HA

4

13

32

4

5

16

1

1

4

2

1

4

How It Operates

Dimensions

1.  When water in the 

house is not being 

used, the LF150A is 

in its normal state, 

where the air charge 

and water pressure 

do not flex the 

diaphragm.

2.  When the water is 

being used, the 

LF150A is still in  

balance of air 

pressure and water 

pressure, the  

diaphragm does  

not flex.

3.  When water is quickly 

shut off, the sud-

den halt causes the 

water pressure to 

soar and the shock 

is absorbed by the 

diaphragm.

   Followed by a sud-

den drop, which 

also acts on the 

diaphragm, flexing it 

silently to handle the 

pressure changes.

4.  Seconds after the 

shock, the diaphragm 

is back in its normal 

stage.

Annual inspection of all water system safety and control valves is 

required and necessary. Regular inspection, testing and cleaning 

assures maximum life and proper product function.

Quick-Closing Faucets

Model LF150A

Model LF150A

Watts Model 2

Model LF150A-HA

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information can result in death, 

serious personal injury, property damage, or damage to the equipment.
Keep this Manual for future reference.

Clothes and Dishwashers

NOTICE

Reviews: