Watts IntelliFlow

®

Automatic Washing Machine Shutoff Valve 
Model A2C-M1, A2C-WB-M1

NOTICE

This unit is not compatible with 240VAC powered washing 

machines or combination washer/dryers that are 240VAC pow-

ered. A Watts A2-IntelliTimer (purchased separately) may be 

used with the IntelliFlow

® 

with washing machines or washer/dry-

ers that are 240VAC powered. (See page 5)

A2C-M1 IntelliFlow

®

Patent Number 6,003,536

Leak Sensor

IS-A2C-M1/A2C-WB-M1

*This valve requires a 120VAC, 60 Hz,  

20 amp ground fault protected circuit.

*Ground Fault Interrupter – A GFI circuit is not 

required for proper operation of the IntelliFlow

®

, but is 

strongly recommended as a safety device.

Operating Instructions

The Watts IntelliFlow

®

  Automatic Washing Machine Shutoff Valve is equipped with a 

state-of-the-art electric current sensing device. When the washing machine is turned 

on, the device senses current flow to the washing machine. This causes it to actuate 

its solenoid water valves, allowing water to flow to the washing machine. When the 

washing machine shuts off upon completion of the full wash cycle, the device senses 

the lack of current and closes the water valves. The IntelliFlow

®

 remains closed until 

the next time you turn the washer on. 
The leak sensor provides additional protection from water damage while the washing 

machine is in operation. Water detected at the sensor results in immediate shut off of 

water flow to the washing machine hose.
By installing an IntelliFlow

®

, you are protecting your home from potential major water dam-

age from a burst or leaking washing machine inlet hose.

Operating Specifications

Electrical Rating:

 120VAC, 60 Hz

Circuit Breaker Requirements:

 20A GFI*

Max. Appliance Current Rating

: 15A

Current Draw:

 20mA (with appliance off)

Electrical Cord:

 6 ft. type SJT 14 AWG

Max. Temperature:

 180°F (82°C)

Max. Pressure:

 150psi (10.3 bar)

Max. Operating Pressure Differential:

  

80 psi (5.5 bar)

Valve Body:

 Reinforced Polysulfone

Rubber Goods:

 Buna-N, EPDM

*Ground Fault Interrupter –

 A GFI circuit 

is not required for proper operation of the 

IntelliFlow

®

, but is strongly recommended as a safety device. In accordance with National 

Electric Code, NFPA 70, Section 210.11 Branch Circuits Required, at least one 20-ampere 

branch circuit shall be provided to supply the laundry receptacle outlets(s) required by 

Section 210.52(F). This circuit shall have no other outlets.

 

WARNING

!

*Surge Protection –

 Although a surge protector is not required for proper operation of the 

IntelliFlow

®

, it is strongly recommended, especially in areas where power surges or lightning 

strikes frequently occur.

Model 

A2C-M1

from  

washing 

machine

Electrical  

power source 

ground fault  

protected

Water supply 

One for cold 

One for hot

Model 

A2C-WB

from  

washing 

machine

Electrical  

power source 

ground fault  

protected

Water supply 

One for cold 

One for hot

Model A2C-M1

1

2

” solder connectors for exposed piping

 

Standardly furnished with 

1

2

” solder copper 

adapters. Either connection may be used for the 

hot or cold water supply.

Model A2C-WB-M1

Includes wall mount box. Wall mount box has water 

inlet connection holes spaced 2

3

8

” center to center. 

Furnished with 

1

2

” solder connectors. Either connection 

may be used for the hot or cold water supply.

Surge Protection – 

Although a surge protector is 

not required for proper operation of the IntelliFlow

®

, it 

is strongly recommended, especially in areas where 

power surges or lightning strikes frequently occur.

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information 

can result in death, serious personal injury, property  

damage, or damage to the equipment.
Keep this Manual for future reference.

WARNING

!

Summary of Contents for IntelliFlow A2C-M1

Page 1: ...ith appliance off Electrical Cord 6 ft type SJT 14 AWG Max Temperature 180 F 82 C Max Pressure 150psi 10 3 bar Max Operating Pressure Differential 80 psi 5 5 bar Valve Body Reinforced Polysulfone Rubber Goods Buna N EPDM Ground Fault Interrupter A GFI circuit is not required for proper operation of the IntelliFlow but is strongly recommended as a safety device In accordance with National Electric ...

Page 2: ...to a house electrical receptacle Figure 4 NOTICE The IntelliFlow requires a 120VAC 60Hz 15 amp ground fault protected receptacle 12 Install Leak Sensor NOTICE The IntelliFlow will detect any current flow to the washing machine when the washing machine is off During startup or at any time during troubleshooting the IntelliFlow valve can be reset to OFF condition by unplugging and reinstalling the l...

Page 3: ...e completed installing wall materials NOTICE Installation must comply with local codes and ordinances Inspection and approval of installation by local authorities may be required prior to installation of wall material Check with local plumbing authorities for requirements 11 Once you ve finished the wall install trim plate connect washing machine water supply hoses to the IntelliFlow valve and to ...

Page 4: ...op of the sensor base until the plug comes to a stop Figure 2 2 Place the sensor base on the floor behind the washing machine as close to the fill hoses as possible Insure that the sensor base is lying flat with all feet in contact with the floor surface 3 Insert the leak sensor plug Figure 1 into the leak sensor receptacle on front panel Figure 2 Note Some washing machine models include circuitry...

Page 5: ...r 10 seconds 4 Turn on washing machine 2 No water flow from one hose either Hot or Cold GREEN LED ON YELLOW LED ON RED LED OFF FAINT BLINK Blink Every 3 Seconds 1 Service strainers on washing machine hoses 2 Service strainers on IntelliFlow see Figure 1 Caution prior to servicing strainers first remove power to IntelliFlow by unplugging then shut off both hot and cold water supply to IntelliFlow 3...

Page 6: ...n nected to the low voltage power supply Activation of the push button on the timer causes current flow which is detected by the IntelliFlow The IntelliFlow then actu ates the solenoid valves allowing water to flow to the washing machine This also begins a timing sequence of two hours which upon its completion de energizes the IntelliFlow shut ting off the flow of water to the washing machine The ...

Page 7: ...hen On will reset the timing circuit FAINT BLINK 3 5 seconds This condition indicates the leak sensor is unplugged To provide the maximum level of protection it is recommended that the leak sensor be installed at all times 7 Sensor Plug What is Surge Protection In many locations changes in the AC voltage supply to the home by the electrical utility company can occur Both lower voltage brownouts an...

Page 8: ...OMPANY MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty and the Company shall not b...

Page 9: ... 3 bares 150 psi Máx diferencial de presión de funcionamiento 5 5 bares 80 psi Cuerpo de la válvula polisulfona reforzada Piezas de goma Buna N EPDM Interruptor de falla a tierra este circuito no es obligatorio para el funcionamiento adecuado de IntelliFlow pero se recomienda utilizarlo como dispositivo de seguridad De acuerdo con el Código Eléctrico Nacional NFPA 70 sección 210 11 que trata la ne...

Page 10: ...ntación de IntelliFlow a un receptáculo eléctrico hogareño Figura 4 AVISO La válvula IntelliFlow requiere un receptáculo con protección de falla a tierra de 120 VCA 60 Hz y 15 amp 12 Instale el sensor de fugas AVISO La válvula IntelliFlow detecta cualquier flujo de corriente hacia la lavadora que se produzca mientras la máquina está apagada Durante la puesta en marcha o en cualquier momento durant...

Page 11: ... finalizado la instalación de los materiales de la pared AVISO La instalación debe realizarse de acuerdo con los códigos y las ordenanzas locales En algunos lugares se requiere la inspección y aprobación de la instalación por parte de las autoridades locales antes de la instalación de los materiales de la pared Consulte a sus autoridades correspondientes para conocer los requisitos 11 Una vez que ...

Page 12: ...an tope Figura 2 2 Coloque la base del sensor en el piso detrás de la lavadora lo más cerca posible de las mangueras de llenado Asegúrese de que la base del sensor esté bien apoyada con todas las patas en contacto con la superficie del piso 3 Inserte el conector del sensor de fugas Figura 1 en el orificio del sensor de fugas del panel frontal Figura 2 Nota Algunos modelos de lavadora tienen circui...

Page 13: ...undos 4 Encienda la lavadora 2 No hay flujo de agua de una manguera ya sea caliente o fría LED VERDE ENCENDIDO LED AMARILLO ENCENDIDO LED ROJO APAGADO PARPADEO DÉBIL Parpadeo cada 3 segundos 1 Coladores de servicio de las mangueras de la lavadora 2 Coladores de servicio en IntelliFlow consulte la figura 1 Tenga cuidado antes de dar mantenimiento a los coladores primero desconecte el IntelliFlow pa...

Page 14: ...ivar el botón del temporizador se genera un flujo de corriente que es detectado por IntelliFlow En consecuencia el dispositivo IntelliFlow activa las válvulas a solenoides y permite que el agua fluya hacia la lavadora Esta misma acción inicia una secuencia de temporización de dos horas que al finalizar desactiva la válvula IntelliFlow y cierra el flujo de agua hacia la lavadora La secuencia de tem...

Page 15: ...ve a encender la lavadora el circuito del temporizador se restablece PARPADEO DÉBIL 3 a 5 segundos Este estado indica que el sensor de fugas está desconectado Para contar con el máximo nivel de protección es recomendable que el sensor de fugas esté instalado en todo momento 7 Conector del sensor Qué es la protección contra sobrecargas En muchos lugares es frecuente que la tensión de CA suministrad...

Page 16: ... IMPLÍCITA LA COMPAÑÍA SE EXIME ESPECÍFICAMENTE A TRAVÉS DE ESTE DOCUMENTO DE CUALQUIER OTRA GARANTÍA EXPLÍCITA O IMPLÍCITA INCLUIDAS ENTRE OTRAS LAS GARANTÍAS IMPLÍCITAS DE COMERCIABILIDAD Y APTITUD PARA UN FIN EN PARTICULAR El recurso descrito en el primer párrafo de esta garantía será el único y exclusivo en caso de incumplimiento de la garantía y la Compañía no será responsable por ningún daño...

Page 17: ...50 psi Différence de pression de service max 5 5 bar 80 psi Corps de robinet polysulfone renforcé Pièces en élastomère buna N EPDM Disjoncteur différentiel de fuite à la terre GFI ce type de disjoncteur n est pas obligatoire pour que l IntelliFlow fonctionne correctement mais ce dispositif de sécurité est fortement recommandé Conformément au Code national de l électricité NFPA 70 Section 210 11 re...

Page 18: ...telliFlow à une prise secteur de la maison Figure 4 AVIS L IntelliFlow exige une prise reliée à la terre de 120 V c a 60 Hz 15 A 12 Installez le détecteur de fuite AVIS L IntelliFlow détecte tous les flux de courant circulant dans la machine à laver lorsque cette dernière est éteinte Au démarrage ou pendant le dépannage le robinet IntelliFlow peut être placé en position d arrêt en débranchant et e...

Page 19: ...évacuation à la recherche de fuites 10 Coupez l alimentation en eau jusqu à ce que vous ayez terminé l installation murale AVIS L installation doit respecter les codes et ordonnances locaux L inspection et l approbation d une installation par les autorités locales peuvent être requises avant l installation murale Vérifiez les exigences requises auprès des autorités de plomberie locales 11 Une fois...

Page 20: ...un arrêt Figure 2 2 Placez la base du détecteur sur le sol sous la machine à laver aussi proche des tuyaux de remplissage que possible Assurez vous que la base du détecteur est bien à plat et que tous ses pieds sont en contact avec la surface du sol 3 Insérez la fiche du détecteur de fuite Figure 1 dans la prise du détecteur de fuite en façade Figure 2 Remarque certains modèles de machines à laver...

Page 21: ...achine à laver sous tension 2 Aucun débit d eau d un tuyau ni chaud ni froid Voyant VERT ACTIVÉ Voyant JAUNE ACTIVÉ Voyant ROUGE DÉSACTIVÉ FAIBLE CLIGNOTEMENT Clignotement toutes les 3 secondes 1 Réparez les crépines sur les tuyaux de la machine à laver 2 Nettoyez les grilles au niveau de l IntelliFlow voir Figure 1 Avant de réparer les crépines assurez vous de retirer l alimentation à IntelLiflow...

Page 22: ...faible tension L activation du bouton poussoir sur le minuteur fait circuler le courant qui est détecté par IntelliFlow IntelliFlow actionne ensuite les électrovannes permettant à l eau de circuler vers la machine à laver Cela commence également une séquence de deux heures qui lorsqu elle est terminée met hors tension l IntelliFlow coupant la circulation d eau vers la machine à laver La séquence d...

Page 23: ...at indique que le détecteur de fuite est débranché Pour fournir un niveau de protection maximal il est conseillé de laisser le détecteur de fuite installé en permanence 7 Prise du détecteur Qu est ce qu une protection contre les surtensions À de nombreux endroits des variations au niveau de l alimentation en courant alternatif fournie par le service public peuvent survenir Une tension plus basse r...

Page 24: ... LA SOCIÉTÉ POUR CE PRODUIT LA SOCIÉTÉ N OFFRE AUCUNE AUTRE GARANTIE EXPRESSE OU TACITE PAR LA PRÉSENTE LA SOCIÉTÉ REJETTE SPÉCIFIQUEMENT TOUTE AUTRE GARANTIE EXPRESSE OU TACITE NOTAMMENT TOUTE GARANTIE TACITE DE QUALITÉ MARCHANDE OU D ADAPTATION À UN BUT PARTICULIER Le recours décrit dans le premier paragraphe de cette garantie constitue le seul recours à toute violation de la présente garantie L...

Reviews: