background image

Installation, Operation and Maintenance Manual

Models: 
Cold Bev Max-S2, Cold Bev Max-S2L, Cold Bev Max-S3L  
Cold Bev Max-S1BBL, Cold Bev Max-S2BBL, Cold Bev Max-S3BBL 

IOM-HS-Cold Bev Max

Important

Please read the entire manual before proceeding with  

the installation and startup. Your failure to follow any  

attached instructions or operating parameters may lead to  

the product’s failure.
Save manual for future reference

Table of Contents

System Specifications  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Replacement Filters  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Notice to Installers  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Installation Precautions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Operation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Filter Cartridge Replacement Procedure   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
Replacement Parts List   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3 
System Drawings   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4 
Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Cold Bev Max-2BBL

Note:

 Do not use with water that is microbiologically unsafe or 

of unknown quality without adequate disinfection before or after 

the system .

Tested and certified by WQA against NSF/ANSI 

Standard 42 for the reduction of claims specified on 

the performance data sheet & NSF/ANSI 372 for "lead 

free" compliance .

Summary of Contents for Hydro-Safe Cold Bev Max-S2

Page 1: ... future reference Table of Contents System Specifications 2 Replacement Filters 2 Notice to Installers 2 Installation Precautions 2 Operation 3 Installation 3 Maintenance 3 Filter Cartridge Replacement Procedure 3 Replacement Parts List 3 System Drawings 4 Limited Warranty 6 Cold Bev Max 2BBL Note Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfe...

Page 2: ... inlet outlet fittings System damage may occur due to high temperature Do not allow the system to freeze Turn off water supply and drain the system if temperature falls below 32 F 0 C Do not install system in direct sunlight or where the system will be exposed to harsh chemicals or may be subjected to being hit by moving equipment carts mops or any other item that may cause damage Allow 3 76mm min...

Page 3: ... and allow it to run to drain for 5 minutes to flush the system then close the valve 9 Open the outlet water valve and check for leaks 10 Record the start up date and pressure gauge values in system maintenance log Note Overtightening components can damage the system causing water damage and or system failure Maintenance Routine maintenance of this system involves periodic filter changes Filter ca...

Page 4: ...4 Cold Bev Max S2 Cold Bev Max S2L Cold Bev Max S3L Cold Bev Max S1BBL ...

Page 5: ...5 Cold Bev Max S2BBL Cold Bev Max S3BBL Note Allow 3 76mm of clearance at bottom of system for removal of filterbowls for filter cartridge replacement ...

Page 6: ...Notes ...

Page 7: ...Notes ...

Page 8: ...and exclusive remedy for breach of warranty and the Company shall not be responsible for any incidental special or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage f...

Reviews: