background image

120-VAC Models: 500650-120CS, -120B, -120BH, and -120BW 

240-VAC Models: 500650-240CS and -240B 

The Watts Radiant 500650 programmable FloorStat will provide both

energy savings and comfor t.

NOTE:

The 500650 face plate must be mounted on a PB112 Series

Power Base.

The FloorStat is designed to control the floor temperature. To avoid dam-

age to your floor, we recommend you follow the supplier’s instructions.

The FloorStat is equipped with an On/Standby switch making it possible

to put the FloorStat in “sleep” mode when its use is no longer required

(i.e., summer). This will not affect the clock or programming.

1. SWITCH SELECTION

This FloorStat is factor y-set to the following default values (      ):

Switch

Function

UP

DN

SW1

Temperature format* 

°F

°C

SW2

Early star t

Disable

Enable

SW3

Time format

12 h

24 h

*If you switch from °F to °C or vice versa, the     ,     , and      setpoints may need 

to be redefined (only if setpoints were modified from their factor y-set default).

When using AUTO mode, the FloorStat calculates the optimum star t time to 

obtain the desired temperature by the set time. The heating system could be 

star ted as early as 6 hours prior to set time when required. The FloorStat will 

automatically re-evaluate (ever y day) the optimum star t time based on the 

previous day’s per formance.

Switches are located on the rear of the face plate. To modify, switch 

UP or DN.

2. MOUNTING FACE PLATE

To mount the face plate onto the power base, refer to the diagrams

below:

To remove the face plate from the power base, inver t steps.

NOTE:

The screw cannot be removed completely.

Owner’s Guide

On/Stand-by switch

GFCI warning light

and test button

Day and Clock settings

Programming Mode PGM

Mode Selection/

Exit Prog.

Floor Temperature

Current Mode and

Setpoint

Current Program No.

Pre-defined Setpoints

Display Backlighting

Button

Increase/Decrease

Temperature

3. FIRST POWER-ON

When power is applied for the first time, the LCD displays: 0:00, 

MO (Monday),     , and floor temperature.

1.

Press 

Hour

Min

to set the current time.

2.

Press 

Day

to set current day.

One of the two following messages may be displayed if the installation 

is incorrect:

• LO:

The floor temperature is below 32°F (0°C), or the temperature 

sensor is defective, or not connected. The heating indicator       is 

displayed and the relay is closed (energized).

• HI:

The floor temperature is above 140°F (60°C), or the temperature 

sensor is defective.

4. GFCI TEST

The GFCI monitors electricity flow for any

loss of current; if there is, the thermostat

will cut-of f power to the heating system. We

recommend you test the GFCI immediately

after installing the control module, and once

a month thereafter to ensure it is operating

properly. To test:

1.

Increase the temperature     until the 

heating indicator      is displayed.

2.

Press TEST:

• Successful: Test warning light is ON 

and power to heating system is cut-of f.

• Unsuccessful: the Test warning light is 

OFF. Cut power to heating system from 

the main power panel and call customer 

ser vice.

3.

When successful, reset FloorStat (On/Standby) to power the 

heating system.

NOTE:

If the warning light comes on during normal operation, cut power

to heating system from the main power panel and have an electrician

verify the installation.

5. TEMPERATURE SETPOINT

The 500650 thermostat is programmed with the following default 

temperature control setpoints:

Symbol

Setting

Default

New

Comfor t 

(when you are at home)

82°F (28°C)

___°__

Economy 

(when asleep or away from home)

68°F (20°C)

___°__

Vacation 

(away for prolonged absence)

50°F (10°C)

___°__

If you wish to modify a setpoint, follow these steps:

1. Set

the desired temperature using the  

buttons.

2. Press and Hold

the      or     or       button.

3.

Release button when symbol is displayed.

4.

Press 

Mode/Ret

to exit.

6. OPERATING MODES

This thermostat has three operating modes:

Automatic

— Executes the Comfor t/Economy 

programs as defined in the schedule.

1.

To activate, press 

Mode/Ret

until      is displayed. A program

icon (e.g.,     ) and corresponding setpoint (e.g.,      or    ) are also 

displayed.

Temporary Bypass

— Maintains a specific temperature until the 

beginning of the next program. Set the desired temperature using the  

OR press      or    to use a pre-defined setpoint. 

Manual

— Maintains a manually-defined setpoint.

1.

To activate, press 

Mode/Ret

until     is displayed. 

2.

Set temperature using         OR press      or     to use Comfor t or 

Economy setpoint.

Vacation

— Maintains the Vacation setpoint when away for a 

prolonged absence (e.g., a vacation). Can also be done remotely 

through your telephone.

1.

Press     to activate.

Correct

Incorrect

Comfort

Economy

Vacation

Higher

Lower

Watts Radiant, Inc.

Programmable FloorStat

04/28/2006

920-115-010-00-1-A

Reviews:

Related manuals for FloorStat 500650-120B