Series WDS-SP-L, WDS-SP-R

FloodSafe

®

 Water Detector Shutoff

Sizes: 

3

4

" and 1" (20 and 25mm)

Please read all instructions, identify all components and read all warnings prior to beginning the installation of this product.
This product is intended to prevent catastrophic water damage in the event of a water heater leak. 

Please Note: 

During an emergency operating condition, the temperature and pressure relief valve installed on your water heater can 

discharge an excessive amount of water.  It is designed to protect your home or business from the potential danger of explosion.  Upon 

detection of this discharged water, the FloodSafe

®

 Water Detector Shutoff shuts off both the supply of water and the source of power 

(gas, oil or electricity) to the water heater, preventing a very dangerous situation.
The FloodSafe

®

 Water Detector Shutoff also contains an audible & visual alarm and contacts for monitored alarm systems.  It is a reset-

table device and can be tested at any time to ensure proper operation.

Parts Included

Important Note:  

Thermostat wiring is required and must be supplied by the installer.

Planning Your Installation:

The Water Detector Shutoff should be installed within 6 to 12 inches of the water heater on the cold water inlet supply pipe.

The Control Unit, which houses the circuitry for the operation of the valve, contains interlocking connectors for the Water Detector Pad, 

the Power Supply and remote alarm and the Power Cutout Module. The cables provided should not be cut or extended; therefore, 

remote installation is not recommended.
The Water Detector Pad supplied with the Water Detector Shutoff should be located as close to the water heater as possible. It is not 

necessary to remove the cover of the Control Unit to install the interconnecting cables. 

Flooring Surface:

 

 Dirt fl ooring –

 A metal or plastic drain pan must be installed under the water heater. Position the Water Detector Pad inside the 

drain pan.

 

 Cement fl oor – 

Install the Water Dam provided with the Water Detector Shutoff installation kit around the outside diameter of the 

water heater. Position the Water Detector Pad inside the Water Dam.

 

 Attic installation – 

A metal or plastic drain pan must be installed under the water heater. Position Water Detector Pad inside the 

drain pan.

Standing Pilot Gas Valves

 – Thermocouples used on some manufactures' gas valves use a left-hand thread instead of the more 

common right-hand thread, Watts has models for each design. Check to be certain that you have the correct model before beginning 

your installation.

Models

WDS-SP-L: Left-hand thread

WDS-SP-R: Right-hand thread

Please be certain to follow all local codes when installing this device.

Control Unit

Power Cutout Module

Power Supply

Pocket Screwdriver

Water Detector Pad

Water Dam

Summary of Contents for FloodSafe WDS-SP-L Series

Page 1: ...houses the circuitry for the operation of the valve contains interlocking connectors for the Water Detector Pad the Power Supply and remote alarm and the Power Cutout Module The cables provided should not be cut or extended therefore remote installation is not recommended The Water Detector Pad supplied with the Water Detector Shutoff should be located as close to the water heater as possible It i...

Page 2: ...it board down The Detector Pad must lie flat on the floor or in a drain pan Route the connecting cable to the Control Unit and insert the interlocking connector to the circuit board Figure 4 Note It is not necessary to remove the cover of the Control Unit to install the interconnecting cables To remove an interlocking cable use the supplied Pocket Screwdriver to depress the tab on the cable while ...

Page 3: ...cts are rated for 150mA Do not exceed this amp range or damage to the Control Unit can occur Exceeding the current rating will void the warranty Figure 13 IMPORTANT Do not insert the Power Supply into the 120 VAC outlet until the installation is complete 6 Insert the green circuit board connector into the Control Unit Figure 14 7 Check the position of the valve reset located on the front of the Co...

Page 4: ...he Company warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment In the event of such defects within the warranty period the Company will at its option replace or recondition the product without charge THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH...

Reviews: