Bob Assistant - Reference Manual
2023-04-04 - Version 1.0
38
4.4.
Change ALARM MESSAGE threshold
Definition
Downlink value (hex) Downlink Port
Alarm Threshold when anomaly > 10%
0x58
1
Alarm Threshold when anomaly > 15%
0x59
1
Alarm Threshold when anomaly > 20%
0x5A
1
Alarm Threshold when anomaly > 25%
0x5B
1
4.5.
Reset battery value
–
New
This Downlink command is a new command for BoB V2
Definition
Downlink value (hex) Downlink Port
Reset battery value to 100%
0x5D
1
4.6.
Enable/disable frame acknowledgement
–
New
In certain conditions where the device is at the limit of the network reach, missing frame might occur
too often. In that case, it is possible to activate frame acknowledge by the network to force retransmission
for frames not getting the acknowledgement by the Network Server. Retransmission will be done 8 times
maximum.
By default, frame ACK is disabled.
Definition
Downlink value (hex) Downlink Port
Enable frame ACK
0x5E
1
Disable frame ACK
0x5F
1
Enabling frame acknowledgement will have some effect on battery lifespan as messages will be re-
sent without acknowledgement reception, and each message will expect an Rx message.