428 Jones Boulevard
Limerick Airport Business Center
Pottstown, PA 19464
INSTRUCTION PART NO. 2437200
REVISION 0
Phone: (610) 495-5131
Fax: (610) 495-5134
Each Watson McDaniel Company Product is warranted against defects in material and workmanship for one year from date of shipment. This warranty extends to the first retail purchaser only. All defective material must be
returned to the person from whom you purchased the Product, transportation prepaid, free of any liens or encumbrances, and if found to be defective will be repaired free of charge or replaced, at the warrantor's or seller's
option. If the material is replaced, any replacement will be invoiced in the usual manner and after inspection of alleged defective material an adjustment will be made for depreciation caused by purchaser's use. In no event will
Watson McDaniel Company be liable to do more than refund the original contract price. Incidental and consequential damages are excluded, whether under this warranty or otherwise. All implied warranties, including warranties
DESIGN
PARAMETERS
LIMITING
OPERATING
CONDITIONS
PMA 900 PSIG up to 800°F
PMO – 650 psig
TMA 800°F @ 900 PSIG
TMO – 662°F
Discharge Temperature Range – 120°F - 390°F
Q
UICK
S
TART
G
UIDE AND
P
RODUCT
N
OTES
A
PPLICATION
-
T
HIS
B
IMETALLIC
S
TEAM
T
RAP OFFERS DISCHARGE TEMPERATURE ADJUSTABILITY BETWEEN
120
°F
AND
390
°F
AND IS GENERALLY USED ON STEAM TRACING AND SMALL PROCESS APPLICATIONS FOR MAXIMUM ENERGY
USAGE
.
O
PERATING
C
HARACTERISTICS
–
A
LTHOUGH IT IS POSSIBLE FOR THE OPERATIONAL CYCLE OF THIS TRAP TO BE
CYCLIC
,
DEPENDING ON THE STABILITY OF THE APPLICATION IT WILL TYPICALLY REACH A POINT OF EQUILIBRIUM AND
HAVE A STEADY DISCHARGE OF CONDENSATE
.
O
RIENTATION
–
T
RAP CAN BE INSTALLED HORIZONTALLY OR VERTICALLY WITH THE FLOW ARROW POINTING IN THE
DIRECTION OF THE FLUID FLOW
.
H
ORIZONTAL INSTALLATIONS SHOULD HAVE THE ADJUSTING SCREW POINTING
UPWARD
.
V
ERTICAL INSTALLATION SHOULD BE WITH FLUID FLOW DOWNWARD ONLY
.
R
EPAIRABILITY
–
T
HIS TRAP IS
I
N
-L
INE
R
EPAIRABLE WITH A
R
EPLACEMENT
T
RAP
C
APSULE
.
C
ONSIDERATIONS
–
U
NLESS A SPECIFIC DISCHARGE TEMPERATURE IS REQUESTED FROM THE FACTORY AT THE TIME
OF ORDER
,
THE STANDARD SETTING FOR THIS TRAP IS
175 °F AT 120 psig.
T
RAP CAN BE MANUALLY FIELD
-
ADJUSTED TO OTHER DISCHARGE TEMPERATURE SETTINGS
.
C
ONSULT THE APPROPRIATE SECTION IN THIS MANUAL
FOR ALTERNATE DISCHARGE TEMPERATURE SETTING INSTRUCTIONS WHILE IN THE FIELD
.
PAGE 1