20.6
PROFIBUS GSD file
The 530Bp, 530BpN, 630Bp, 630BpN and 730BpN pumps can be integrated into a PROFIBUS DP V0
network using a General Station Data (GSD) file. The file identifies the pump and contains key data
including its communication settings, the commands it can receive and the diagnostic information it can
pass to the PROFIBUS master on interrogation.
The GSD file — WAMA0F70.GSD — can be downloaded from the Watson-Marlow website and installed;
or typed into a PROFIBUS master directly from this manual using a GSD editor program.
Note: The data-flow to and from the pump may need to be byte-reversed, due to differences of
handling the data between suppliers of master devices.
;
;*************************************************************************
;* =============================================================== *
;* *
;* Watson-Marlow Bredel Pumps *
;* Bickland Water Road *
;* Falmouth *
;* Cornwall *
;* TR11 4RU *
;* Tel.: +44(1326)370370 *
;* FAX.: +44(1326)376009 *
;* *
;* =============================================================== *
;* Filename: WAMA0F70.GSD *
;* GSD file version 3 from 2013-09-24 *
;* ---------------------------------------------------------------------------- *
;* *
;*************************************************************************
#Profibus_DP
GSD_Revision = 3
Vendor_Name = "Watson Marlow"
Model_Name = "530/630/730 Profibus Pumps"
Revision = "Version 1.00"
Ident_Number = 0x0F70
Protocol_Ident = 0
Station_Type = 0
m-630bpn-en-08